![Festo CMMD-AS series Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_installation-manual_2283097097.webp)
5. Mechanical installation
Festo P.BE-CMMD-AS-HW-EN 1002NH
97
5.
Mechanical installation
5.1
Important instructions
Note
Use the CMMD-AS motor controller only as a device to be
mounted in a control cabinet
The mounting position is vertical with the power supply lines
[X9] leading upwards.
Mount it with the mounting brackets on the control cabinet
plate.
Mounting clearance:
For sufficient ventilation, 100 mm of clearance to other
assemblies is required above and below the device.
The motor controllers of the CMMx family are designed such
that they can be mounted on a heat-dissipating mounting panel
if used as intended and installed correctly. We wish to point out
that excessive heating can lead to premature aging and/or
damage to the device. If the CMMD-AS motor controller is
subject to high thermal loads, a mounting clearance (hole
interval) of 73 mm is required!