![Festo CMMD-AS series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/festo/cmmd-as-series/cmmd-as-series_installation-manual_2283097051.webp)
3. Product description
Festo P.BE-CMMD-AS-HW-EN 1002NH
51
3.7.3
I²t function
An integrator monitors the current²-time integral of the motor controller. As soon as the
parameterized time is exceeded, a warning message is output and the maximum current is
limited to the rated current.
3.7.4
Positioning controller
A positioning control system is set above the current controller. Up to 64 positions
( 63 positions) can be selected per axis and run via a trajectory generator.
There are also volatile position data records for positioning via the fieldbus.
The position records are made up of a position value and a motion profile. The following
parameters can be set for the eight positioning profiles:
-
Travel speed
-
Acceleration
-
Delay
-
Smoothing
-
Time
-
Start delay
-
Final speed
-
Wait for current positioning, reject or ignore initial instruction.
From every position record, any other position record can be started directly. You can
transition to a new position record without first coming to a standstill.
The parameter sets can be called up as follows:
-
over digital inputs (position record 0 ... 63 per axis)
-
over the RS232 interface (for test purposes only) or
-
over a fieldbus interface.
Содержание CMMD-AS series
Страница 2: ......
Страница 75: ...3 Product description Festo P BE CMMD AS HW EN 1002NH 75 For linear axes For rotational axes ...
Страница 91: ...4 Functional safety engineering Festo P BE CMMD AS HW EN 1002NH 91 4 3 5 Parameterization example FCT ...
Страница 93: ...4 Functional safety engineering Festo P BE CMMD AS HW EN 1002NH 93 4711d_21 Fig 4 8 Sample circuit SS1 CMMD AS ...
Страница 99: ...5 Mechanical installation Festo P BE CMMD AS HW EN 1002NH 99 Fig 5 2 Motor controller CMMD AS Mounting ...