4. Functional safety engineering
78
Festo P.BE-CMMD-AS-HW-EN 1002NH
Among other issues, the EN 60204-1 standard deals with the handling of emergencies and
defines the terms EMERGENCY OFF and EMERGENCY STOP (see table).
Handling
Definition (EN 60204-1)
Danger case
EMERGENCY
OFF
Electrical safety in case of emergency by
switching off the electrical energy to all or
part of the installation.
EMERGENCY OFF is to be used where a risk
of electric shock or other electrical risk
exists.
EMERGENCY-
STOP
Functional safety in an emergency by
bringing a machine or movable parts to
a standstill.
EMERGENCY STOP is used to stop a process
or a motion if this creates a danger.
Table 4.1 EMERGENCY OFF and EMERGENCY STOP as per EN 60204-1
The standard EN 61800-5-2 describes various safety functions that can be used
dependent on the application.
For the position controllers of the CMMD-AS family, the STO and SS1 safety functions
have been implemented through external circuitry.
Galvanic isolation does not occur with the STO function. As a result, this does not have
any protective function against electric shock. In the sense of the standards, an
EMERGENCY-OFF system cannot be implemented with the STO, because this requires the
complete system to be switched off via a mains power isolator of some kind (main power
switch or mains circuit breaker).
Safety function as per
EN 61800-5-2
PILZ component
Switch-off behaviour Stop category in
accordance with
EN 60204-1
STO
Safe Torque Off
PNOZ X2P
Relay outputs forced:
-
2 safety contacts no delay
Connection options for:
-
EMERGENCY STOP buttons
-
Protective door limit switches
-
Start button
0
SS1
Safe Stop 1
PNOZ XV2P
Relay outputs forced:
-
2 safety contacts no delay
-
2 safety contacts relapse
delayed
Connection options identical
to X2P
Fixed or adjustable relapse delay
Cancelling the time delay through
Reset button
1
Table 4.2 Overview of the safety function in accordance with EN 61800-5-2
Содержание CMMD-AS series
Страница 2: ......
Страница 75: ...3 Product description Festo P BE CMMD AS HW EN 1002NH 75 For linear axes For rotational axes ...
Страница 91: ...4 Functional safety engineering Festo P BE CMMD AS HW EN 1002NH 91 4 3 5 Parameterization example FCT ...
Страница 93: ...4 Functional safety engineering Festo P BE CMMD AS HW EN 1002NH 93 4711d_21 Fig 4 8 Sample circuit SS1 CMMD AS ...
Страница 99: ...5 Mechanical installation Festo P BE CMMD AS HW EN 1002NH 99 Fig 5 2 Motor controller CMMD AS Mounting ...