MACHINES AND
ACCESSORIES
Page 18 of 29
Assembly of the connecting pipes:
Pipe 1: Remove the cap from the connecting
pipe (Ref. 58 in the figure) and then insert the
O-ring (Ref. 45 in the figure). In the
meantime, remove the cap from the cylinder
unit (Ref. 37 in the figure) and attach the
connecting pipe (Ref. 58 in the figure)
tightening securely to prevent leakage.
Pipe 2: Connect the O-ring (Ref. 45 in the
figure) to the pressure gauge (Ref. 43 in the
figure) and then attach it to the connecting
pipe (Ref. 59 in the figure) tightening
securely.
Then install the two levers in their appropriate
housing, screwing in the locking bolts.
Figure 11 – Installing the
connecting pipes.
Air outlet valve
Before proceeding with the assembly open the air vent valve inside the cylinder (Ref. 61)
5. Move the manual winch (Ref. 11 in the figure)
into position next to the machine and connect it
to the bracket (Ref. 34 in the figure) using the
screws (Ref. 02 in the figure), washers (Ref. 06
in the figure), spring lock washers (Ref. 05 in
the figure) and the nut (Ref. 04 in the figure).
Tighten
securely
to
avoid
any
possible
loosening.
Figure 12 – Manual winch
installation.
Parts list
Refer to the parts list and its technical drawings to verify the presence of all the parts
necessary for the proper assembly of the machine.
fervi.com