73
EN
Cod. 3541T090 - Rev. 00 - 06/2019
BOILER CONTROLLER - SERVICE MENU
Procedure for modifying parameters SC12 and SC13:
• Put the boiler in heating or DHW mode and press the Reset button (ref. 6 fig. 151) for 10 seconds.
• Then press the “DHW +” button (ref. 2 fig. 151) to set 123.
• Press the Reset button (ref. 6 fig. 151) once.
• The display shows Ts flashing; press the “h” button (ref. 4 fig. 151) once.
• The display shows Sc flashing; press the reset button once.
• The display shows Sc alternating with 01 flashing;
• Press the “h” button (ref. 4 fig. 151) until displaying Sc alternately with 15 flashing;
• Press the “DHW +” button and the display shows “00”;
• Press the “DHW +” button until the display shows “03”;
• Press the “h” button (ref. 4 fig. 1) to confirm and the 100% calibration mode will activate displaying the message “CA” and “LI” alternating.
• after just over a minute the calibration mode will end and the display will show “C” alternating with “12” with the continuous flame symbol.
• press the “DHW +” or “DHW -” button to set the “SC12” parameter value to the value that allows CO2 optimisation.
• press the “h” button to confirm the value. The display shows “CA” and “LI” alternately to indicate that a further calibration is being performed.
• after just over a minute the calibration mode will end and the display will show “C” alternating with “15” with the continuous flame symbol.
• press the “DHW +” or “DHW -” button to set the “SC13” parameter value to the value that allows CO2 optimization.
• press the “h” button to confirm the value. The display “SC” appears alternately to “15”.
• Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service Menu, or exiting occurs automatically after
15 minutes
• put the boiler in TEST mode and check the CO2 value at maximum and minimum power with an analysis instrument.
“In” - Information Menu
12 pieces of information are available.
Press the Heating buttons to scroll the list of information in increasing or decreasing order. Press the DHW buttons to display the value.
Contents
Description
Range
t01
NTC hot water outlet sensor (°C)
0÷125 °C
t02
NTC hot water inlet sensor (°C)
0÷125 °C
t03
NTC DHW sensor (°C)
0÷125 °C
t04 (not used)
NTC External sensor (°C)
+70 ÷ -30°C (negative values flash)
t05
NTC Fume sensor (°C)
0÷125 °C
F06
Actual fan rpm
00÷120 x100RPM
L07
Actual burner power (%)
00%=Min., 100%=Max.
F08
Actual DHW drawing (l/min/10)
00÷99 l/min/10
P09
Actual system water pressure (bar/10)
00=With Pressure switch open,
14=With Pressure switch open, 00-99 bar/10 with Pressure transducer
P10
Actual modulating pump speed (%)
00÷100%
P11
Burner operating hours
00÷99 x 100 hours
F12
Flame status
00÷255
Notes
:
In case of damaged sensor, the card displays hyphens.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service Menu, or exiting occurs automatically after 15
minutes.
“Hi” - History Menu
The card can store the last 8 faults: the History datum item H1 represents the most recent fault that occurred, whereas the History datum item H08 represents the
least recent.
The codes of the faults saved are also displayed in the relevant menu of the Remote Timer Control.
Press the Heating buttons to scroll the list of faults in increasing or decreasing order. Press the DHW buttons to display the value.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service Menu, or exiting occurs automatically after 15
minutes.
“rE” - History Reset
Press the Winter/Summer/Off-On button for 3 seconds to delete all faults stored in the History Menu: the card automatically exits the Service Menu, in order to confirm
the operation.
Press the Reset button for 10 seconds to exit the card Service Menu, or exiting occurs automatically after 15 minutes.
Содержание OMNIA HYBRID C
Страница 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Страница 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Страница 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Страница 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Страница 52: ...52 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU REMOTE CONTROLLER FOR SERVICEMAN MENU ...
Страница 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Страница 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Страница 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Страница 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Страница 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 115: ...115 EN Cod 3541T090 Rev 00 06 2019 ...