71
EN
Cod. 3541T090 - Rev. 00 - 06/2019
BOILER CONTROLLER - SERVICE MENU
0=Disattivato
Descrizione
Range
Default
P48
DHW maximum power (b02=1)
0-100%
100%
DHW maximum power (b02=2)
0-100%
100%
DHW maximum power (b02=3)
0-100%
94%
DHW maximum power (b02=4)
0-100%
100%
P49
Comfort1 standby time (b01=1)
0-100minutes
20 minutes
Not implemented (b01=2)
--
--
Not implemented (b01=3)
--
--
Not implemented (b01=4)
--
--
P50
Comfort2 standby time (b01=1)
0-100 minutes
42 minutes
Not implemented (b01=2)
--
--
Not implemented (b01=3)
--
--
Not implemented (b01=4)
--
--
P51
Solar deactivation temperature (b01=1)
0-100°C
10°C
Setpoint deltaT (b01=2)
0-20°C
0°C
Solar deactivation temperature (b01=3)
0-100°C
10°C
Setpoint deltaT (b01=4)
0-20°C
0°C
P52
Solar ignition temperature (b01=1)
0-100°C
10°C
DHW ramp (b01=2)
1-20°C/minute
5°C/minute
Solar ignition temperature (b01=3)
0-100°C
10°C
DHW ramp (b01=4)
1-20°C/minute
5°C/minute
P53
Solar standby time (b01=1)
0-255 seconds
10 seconds
No effect on adjustment (b01=2)
0-255 seconds
0 seconds
Solar standby time (b01=3)
0-255 seconds
10 seconds
No effect on adjustment (b01=4)
0-255 seconds
0 seconds
P54
Heating deltaT temperature adjustment (b01=1)
0-60°C
18°C
Heating deltaT temperature adjustment (b01=2)
0-60°C
18°C
Heating deltaT temperature adjustment (b01=3)
0-60°C
18°C
Heating deltaT temperature adjustment (b01=4)
0-60°C
18°C
P55
Primary exchanger protection temperature (b01=1)
0-150°C
43°C
Primary exchanger protection temperature (b01=2)
0-150°C
43°C
Primary exchanger protection temperature (b01=3)
0-150°C
43°C
Primary exchanger protection temperature (b01=4)
0-150°C
43°C
P56
System min. pressure value
0-8bar/10 (Only for boilers with water pressure sensor)
4 bar/10
P57
System nominal pressure value
5-20bar/10 (Only for boilers with water pressure sensor)
7 bar/10
P58
Exchanger protection intervention (b01=1)
0=No F43, 1-15=1-15°C/second
10°C/second
Exchanger protection intervention (b01=2)
0=No F43, 1-15=1-15°C/second
10°C/second
Exchanger protection intervention (b01=3)
0=No F43, 1-15=1-15°C/second
10°C/second
Exchanger protection intervention (b01=4)
0=No F43, 1-15=1-15°C/second
10°C/second
P59
Heating hysteresis after ignition
6-30°C
30°C
P60
Timer for heating hysteresis after ignition
60-180 seconds
60 seconds
P61
Pump deactivation with OpenTherm (ATTIVE ONLY WITH FW
3)
0-1
0
Note:
1.
Parameters with more than one description vary their function and/or range in relation to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the parameter given in brackets is modified.
3.
The Maximum Heating Power parameter can also be modified in Test Mode.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 seconds to exit the card Service Menu, or exiting occurs automatically after 15
minutes.
Содержание OMNIA HYBRID C
Страница 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Страница 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Страница 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Страница 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Страница 52: ...52 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU REMOTE CONTROLLER FOR SERVICEMAN MENU ...
Страница 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Страница 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Страница 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Страница 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Страница 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 115: ...115 EN Cod 3541T090 Rev 00 06 2019 ...