HEAT PUMP ELECTRONIC BOARD
19. HEAT PUMP ELECTRONIC BOARD
19.1 Electronic board’s DIP switch settings of the of the heat pump
The DIP switch are located on the electronic board inside the unit’s electrical panel.
WARNING -Switch off the power supply before opening the switch box service panel and making any changes
to the DIP switch settings..
DIP SWITCH
Description
ON
OFF
S1 (1)
Set always OFF
50m
5m
S1 (2)
Set always OFF
Installed
Installed
S1 (3)
Electrical booster (IBH1-first stage) (OFF if installed)
Not installed
Installed
S1 (4)
Electrical booster (IBH2-second stage) (OFF if installed)
Not installed
Installed
S2 (1)
Temperature probe (necessary if AHS-gas boiler is installed, in this case set ON)
Installed
Not installed
S2 (2)
Set always OFF
/
/
S2 (3)
Set always OFF
/
/
S2 (4)
Set always OFF
/
/
Table. 10 - Dip switch configuration (see part 13 “fig. 203 -”).
DIP SWITCH
ID
FACTORY DIP SWITCH SETTING*
OFF
ON
1 2 3 4
1 2 3 4
S1
S2
fig. 202 -
S1
1
OFF
2
OFF
3
ON
4
ON
S2
1
ON
2
OFF
3
OFF
4
OFF
*: Do not change the dip-switch settings.
PCB-1 - Hydraulic module control board heat pump
3
2
1
2
3 4 5
6
7
8
11
9
10
12
13
14
23
24
25
26
27
15
17
18
16
19
20
21
22
fig. 203 -
1 Input port for solar energy(CN5)
2 Output port for transformer(CN4)
3 Power supply port for user interface(CN36)
4 Port for remote switch(CN12)
5 Port for flow switch(CN8)
6 Communicate port between door PCB B and door PCB(CN14)
7 Communicate port between door PCB and user interface(CN19)
8 Port for temperature sensors(TW_out, TW_in, T1, T2,T2B )(CN6)
9 Port for temperature sensor(CN13)
10 Port for temperature sensor(T1B, the final outlet temp.)(CN15)
11 Digital displays(DIS1)
12 Check button(SW4)
13 DIP switch(S1,S2)
14 output port for deforst(CN34)
15 Port for anti-freeze eletric heating tape (internal)(CN40)
16 Port for anti-freeze eletric heating tape (internal)(CN41)
17 Output port for external heating source / operation output port(CN25)
18 Port for anti-freeze eletric heating tape(external) /port for solar
energy pump/output port for remote alarm(CN27)
19 Port for external circulted pump/pipe pump/mix pump/2-way
valve SV2(CN37)
20 Port for SV1(3-way valve) and SV3(CN24)
21 Port for internal pump(CN28)
22 Input port for transformer(CN20)
23 Feedback port for temperature switch(CN1)
24 Port for power supply(CN21)
25 Feedback port for external temp. switch(shorted in default)(CN2)
26 Control port backup heater/booster heater(CN22)
27 Control port for room thermostat(CN3)
Содержание OMNIA HYBRID C
Страница 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Страница 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Страница 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Страница 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Страница 52: ...52 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU REMOTE CONTROLLER FOR SERVICEMAN MENU ...
Страница 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Страница 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Страница 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Страница 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Страница 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 115: ...115 EN Cod 3541T090 Rev 00 06 2019 ...