6
EN
Cod. 3541T090 - Rev. 00 - 06/2019
GENERAL FEATURES
1.3 Components supplied with the indoor unit
Description
Shape
Q.ty
Installation, maintenance and user manual (this manual)
1
Square cock with filter (system return)
1
Square cock (system outlet)
1
Remote control
1
Energy label
Y IJA
IE IA
RVL-I PLUS 5
A
63 dB
7
5
kW
5
5
5
kW
5
811/2013
2015
B
C
D
E
F
G
A
35°C
A
A
++
+
+
55°C
+
A
+ +
- dB
3*
*
The unit is supplied with 3 energy labels (use only that one of the installed system).
1.4 Components supplied with the outdoor unit
Description
Shape
Q.ty
Condensate water drain to be installed under the unit basement
1
1.5 Remote control
The user interface consists of a wired remote controller (up to 50 m from the unit)
which allows the management of:
- HEATING AND COOLING SYSTEM. The unit, if activated in heat or cool mode,
works by modulating the frequency of the compressor to maintain the temperature
of the produced water to the setpoint value set by the controller. Through para-
meter you can use the remote controller (eg. For single-zone systems) as a room
thermostat.
- HEATING WITH BOILER. As a function of the set parameters, can be activeted
in integration or substitution of the heat pump. The electronic board will activate
the boiler in case the heat pump does not work.
- SILENCED MODE: according to a programmed schedule, this reduces the ma-
ximum frequency of the compressor and the fan speed, to reduce the generated
noise and the power absorbed by the unit.
- ON / OFF using an external contact. The unit can be turned on and off (eg. ther-
mostat / remote switch) via an external contact: in this case the unit will operate in
the mode set by the controller keyboard.
- HEAT / COOL via external contacts. The unit can be activated in heat or cool
mode via two external contacts (eg. thermostat that manages the heat and cool
demand / remote switch).
- ECO MODE: possibility of defining a time slot in hot mode where the heat pump
runs with a sliding setpoint defined by the chosen climatic curve. There are 8 cli-
matic curves for low temperature systems (radiant floor) and 8 climatic curves for
fan coil or radiator systems).
- WEEKLY PROGRAMMING: this makes it possible to set a different schedule for
each day of the week defining the operating mode for each time slot (COLD/HOT)
and the work setpoint.
fig. 1 -
Содержание OMNIA HYBRID C
Страница 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Страница 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Страница 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Страница 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Страница 52: ...52 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU REMOTE CONTROLLER FOR SERVICEMAN MENU ...
Страница 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Страница 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Страница 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Страница 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Страница 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...
Страница 115: ...115 EN Cod 3541T090 Rev 00 06 2019 ...