40
DOMINA PLUS F 24 - 30 E
FERELLA EXTRA F 24 - 30 MEL
Version - 09.2002
Position
System delivery temperature increase
adjustment. Setting: 10°C/min.
(range 1 to 20°C/min.)
6
10
This permits changing the speed of increasing the delivery temperature.
Position
Heating power adjustment.
Setting: 100%
(range 0 to 100%.)
7
100
Indicates the percentage difference between the minimum and maximum boiler power.
Position
Adjustment of idle time after switching off
heating.
Setting: 2 min.
(range 0 to 10 min.)
8
2
Position
Adjustment of idle time after tap water
operation
Setting: 120 sec.
(range 0 to 255 sec.)
9
120
Position
Adjustment of power during ignition phase.
Setting: 50%
(range 0 to 100%.)
10
50
Indicates the percentage difference between the minimum and maximum boiler power.