Version - 09.2002
Calculation example
Here we give an example of the calculation for a separate fume
outlet. We recommend inserting a condensate trap on long
vertical sections to prevent condensation getting onto the
burner and damaging it. If monitoring the condensate trap is
not guaranteed, it must be fitted with a suitable drain pipe and
air trap, which in its turn must be appropriately connected to
a suitable drain.
Ref.
1
2
3
4
5
6
No. Pieces
1
1
1
1
36
1
Air bend Ø80
Horizontal air pipe Ø80
Windproof end piece
Condensate collection cup coupling
Vertical fume pipe Ø80
Outlet flue + coupling
Description
Equivalent
loss
1.5 m
1.0 m
2.0 m
3.0 m
36.0 m
4,0 m
47.5 m
Total
1
2
3
4
5
6