3.17 Ferroli Domina boiler programmer fixing (optional)
CLOCK
X8
4
3
2
1
2
1
X3
X4
X5
OTC
X10
1 2 3
1 2
1 2
X6
X7
10
1
X1
X2
2
2
1
2
3
4
9 8 7 6 5 4
3 2 1
1
3
Terminal 4 & 5 situated underneath the
boiler in the terminals compartment
Terminals for integral clock situated inside
circuit board compartment
Existing wiring
- Remove outer case by removing two securing screws from the rear bottom corners and lift off.
- Remove screw securing facia panel and swing facia panel down.
- Remove rear cover from facia.
- Remove clock blanking plate from the boiler facia panel.
- Mount clock into facia panel using two screws provided.
- Take the black cable containing the blue and brown wires and connect the loose spades to clock
terminals 1 & 2.
- Connect the plug end of the cable to terminal X4 of main circuit board.
- Remove the connector link from the 2 wires located behind the clock position.
- Connect these to terminal 3 and 5 of the clock.
- Replace everything in reverse order.
- Please refer to page 66 of User manual for use of time clock