For rear outlet
c
c
c
For upper outlet
d
c
d
d
-
c
For upper outlet
Common
For rear outlet
Take off the four screws which fix the top sealed chamber cover, remove the cover and gasket. Rotate the
cover and gasket through 90
°
and fit it to the rear of the boiler to cover the original flue outlet. Secure
them both in place with the four screws removed previously.
Fig. 17c
Fig. 17d
Fig. 17e
Remove fan mounting plate by undoing the three fixing screws c. Rotate the fan through 90
°
so that the
fan nozzle points upward. Secure the fan to the plate in the new position using screws in position d.
3
4
Fig. 17f
Fig. 17g