Boiler information menu [Diagnostic]
This menu provides the information, in real time, of the various sensors present in the boiler.
To access it, press the button
from the main screen, select the item
[Diagnostic]
and confirm with the button
.
fig. 19
Table 1 - Description - Boiler information menu [Diagnostic]
If the sensor is damaged or disconnected, the display will show dashes (--).
To return to the main screen, repeatedly press the button
or wait for automatic switching after 15 minutes.
Parameter displayed
Description
Range
[CH 1 temp]
NTC Flow sensor (°C)
0 ÷ 125 °C
[CH 2 temp]
NTC Return sensor (°C)
0 ÷ 125 °C
[DHW temp]
NTC DHW sensor (storage tank probe) (°C)
0 ÷ 125 °C
[Ext temp]
NTC External sensor (°C)
+70 ÷ -30°C
[Fume temp]
NTC Fume sensor (°C)
0 ÷ 125 °C
[Fan rpm]
Actual fan rpm
0 ÷ 9999 RPM
[Pump speed]
Actual modulating circulating pump speed (%)
00% = Min., 100% = Max.
[Power]
Actual burner power (%)
0 ÷ 100 %
[DHW flow]
Actual DHW draw (l/min)
00 ÷ 99 l/min
[Water Pressure]
Actual system water pressure (bar)
0.0 ÷ 9.9 bar
[Flame]
Flame status
-- ÷ 255
DIAGNOSTIC
DIAGNOSTIC
CH 1 temp
CH 2 temp
DHW temp
Ext temp
Fume temp
Fan rpm
Pump speed
Power
27
°C
26
°C
25
°C
--
°C
28
°C
0
rpm
0%
--%
Ext temp
Fume temp
Fan rpm
Pump speed
Power
DHW flow
Water Pressure
Flame
--
°C
28
°C
0
rpm
0%
--%
0,0
l/min
0,8
bar
--