10.2.2 Dismantling impeller
1.- Support the impeller with suitable lifting
equipment.
2.- Hub with circumferential extraction groove:
remove the central impeller fixing bolt (Photo 28).
Hub with threaded extraction holes: partially
unscrew the central fixing bolt.
Photo 28
3.- Hub with circumferential extraction groove:
position the tip of the threaded rod of the extractor
and hook the grips onto the extraction groove of the
impeller hub (Photo 29a).
Hub with threaded extraction holes: screw the
peripheral bolts into the threaded holes on the hub
and rest the tip of threaded rod of the extractor on
the head of the impeller fixing bolt (Photo 29b).
Photo 29a
Photo 29b