FENIX IMVICO SM2000 OPERATION MANUAL
12/65
The SM2000 printer includes a connector cover in order to protect the cable connections from shock and
dirt. At the same time, it avoids user contact.
Once all the cables are connected, follow these steps for its installation:
1.
The connector cover has three openings: left, right and rear. If needing to use any of the
side openings, remove the corresponding tab by breaking it with your fingers (once a tab
has been removed, it can no longer be reinstalled).
2. After removing the tab, be sure to remove any remaining piece of plastic in order to
keep the plastic border flat and avoid any possible cable harm.
3. Place the cover to its default position and assemble the two fixing screws as shown in
the following figure:
Fig. 2.3-
Connectors cover
2.2- POWER SUPPLY
The SM2000 is powered by an external power supply by means of a female polarized connector of 3
pins that includes a security anchor. The power supply voltage must be verified before making the
connection between the supply and the printer.
Fig. 2.4-
SM2000 printer power supply connector
The power supply male connector must be a KYCON
806-KPP-3P
or an equivalent model.
It is not advisable to use a different power supply from the one provided by FENIX along with the printer
(FAPOS-1). Using a different power supply could harm the printer or prevent it from working properly.
NOTE
:
The current flow increases when the number of active dots in a horizontal graphic line increases. Print
quality can decrease if the printing ratio and the printing speed are high.
If the average workload of the printer is high during a long period of time, it is recommended to use the
low consumption mode (see DIP-switches 2-3, 2-4).
+24v
GND
nc
Frame
GND
Fixing
screws
Lateral tab
Connector
cover