EPC1800 SERIES OPERATION MANUAL
●
If communications setting are changed it will be required to change them also in the
host controller in order to reestablish communications.
●
The number and order of setting changed it is not important.
Feature
s (high nibble)
s (low nibble)
value
1- Paper width
0
Not supported
Not supported
2- Baudrate
1
0
9600 bauds
1
19200 bauds
2
38400 bauds
3
115200 bauds
4
230400 bauds
3- Parity
2
0
Odd parity
1
Even parity
2
No parity
4- Handshaking
3
0
Hardware
1
Xon/Xoff
2
No handshake
5- Cutter
4
Not supported
Not supported
6- Printing density
5
0
Normal
1
Light
2
Dark
7- Black Mark
6
Not supported
Not supported
8- Carriage return
7
0
Enable
1
Disable
9- Near-end paper sensor
8
Not supported
Not supported
[Example]
The following command will change baudrate to “115200 bauds”, parity to “Even” and
handshake to “No handshake”.
13
1B
1C
1D
03
13
21
32
handshake
parity
baudrate
number of setting
If all the features are supported by the printer, it will print the following message on
paper:
Feature saved successfully-> 2
Feature saved successfully-> 3
Feature saved successfully-> 4
ESC
SP
n
[Name]
Set right-side character spacing
[Format]
ASCII
ESC
SP
n
Hex
1B
20
n
Decimal
27
32
n
[Range]
<00>H
≤
n
≤
<FF>H