 FORMS OF MESSAGES SENT 

 

Info SP 

Information about the status of the control unit 

Teplota xx SP 
(Temperature xx 
SP) 

Change in the required temperature (where only whole numbers are set in 
the place of xx, within the range of the permitted maximum and minimum 
temperatures) 

Off SP 

The SP elements are switched off - for the cancellation of this function, use 
the Teplota xx SP (Temperature xx SP) message (if it is in the AUTO 
mode, this status is valid until the next change given by the programme). 

 

 

Zavolej (Call) 

Return call 

 

xx = the temperature value in ºC (always a two-digit number, for example 05) 
 
! For the sending and reception of return messages, any type of mobile phone can be used!! 
If the telephone has the option of setting the letter size (format), always use the MEDIUM size when 
writing the messages (three optional sizes) or the LARGE size (two optional letter sizes). 
 

FORMS OF RETURN MESSAGES FROM THE CONTROL UNIT 
 

Zadana: xx.x  
(Set: xx.x) 

is the required temperature (set by the user) 

Akt: xx.x 

is the current room temperature 

Zapnuto (Switched on) 
Vypnuto (Switched off 

heating system switched on (On) 
heating system switched off (Off) 

AUTO 
MANU 

automatic mode AUTO 
manual mode MANU 

Sig:x 

determines the signal level in the position of the module where x are 
values in the range of 0 to 5: 
0… cannot be determined or no signal detected 
1… the worst signal level 
5… the best signal level 

Baterie! (Battery!) 

Signalizes a flat battery in the central unit 

Nespravne zadana sms nebo 
nelze identifikovat zvolene 
zarizeni (Text message has 
not been entered correctly or 
the selected appliance cannot 
be identified) 

Wrongly written text message or a connection error 

 

xx.x 

= the temperature value in ºC  

RETURN MESSAGES ARE SENT WITHIN 3 MINUTES! 

Note: 

If the min./max. temperature in the room is exceeded (the set CONST1 AND 2, see the BPT-SP 

instructions manual, p. 9), a “WARNING” text message is sent automatically in the Info form. 
 

Info: 

When using a pre-paid card, it is necessary to make a paid phone call once every 3 months. This 

call is carried out automatically (after 80 days between 4 p.m. and 9 p.m.) to the number which is stated in 
the control unit (CONST 12) and the call will be terminated automatically after 20 seconds. You can also 
carry out this function earlier, using the “

Zavolej

” (Call) text message. 

Содержание BPT-SP

Страница 1: ...eless control unit Two way radio communication at 433 92 MHz A convenient solution for the heating of a room Predictive system guarantees the set temperature at the required time Energy cost savings d...

Страница 2: ...eless receiver concealed switches on the heating appliance based on received information about the current and required temperature from the control unit sends back confirmation of the executed change...

Страница 3: ...lace the ACTIVATION of each element added to the system As the whole system operates on the bidirectional radio frequency of 433 92 MHz follow the instructions for the installation and placement of ea...

Страница 4: ...unctional adhere to the correct polarity which is shown in the space for batteries when changing the batteries when the batteries need to be changed it is indicated on the display by the flashing symb...

Страница 5: ...boiler in the AUTO mode switching between the programmes in the PROG mode switching between the constants in the CONST mode switching between the temperatures and in the MANU mode addition of an eleme...

Страница 6: ...lained in detail for each mode line 4 economy temperature indicator in the MANU mode summer mode symbol see page 9 comfort temperature indicator in the MANU mode error message error notification non f...

Страница 7: ...ton the operational clock is cleared LCD display options Line 1 current day Line 3 from the left current time or error states required temperature or programme number Line 5 current temperature and se...

Страница 8: ...6 periods in a day move on to the next day by successive pressing of the i button or by using the Day button Copying of days in the PROG mode This is used to speed up the programming A programme from...

Страница 9: ...M SUMMER MODE Select one of the following modes using the T buttons and confirm it with the i button Option 0 normal mode Normal operation of the heating system without advance start up of the heating...

Страница 10: ...will start functioning For example the required temperature is 22 0 C and the zone of proportionality is 1 5 C Up to a temperature of 20 5 C the source will give out maximum heat After this value has...

Страница 11: ...um number of elements in the whole system is 255 press the F and T buttons and select the ACTIV mode confirming it with the i button the option to select the programme for switching elements PROGR wil...

Страница 12: ...programme by pressing the Test button you can find out the HEATING NOT HEATING status of the appliance you can find out information about the other elements by pressing the H buttons OTHER FUNCTIONS H...

Страница 13: ...re increases it will return back to the set mode CONNECTION OF THE GST1 MODULE You can add a GST 1 GSM module to the system which will enable remote control of the control unit via a mobile phone With...

Страница 14: ...vation 3 Insert an activated SIM card into the GST module The SIM card holder can be found in the back part after the cover has been opened at the location marked by an arrow see page 2 of the GST1 in...

Страница 15: ...n Vypnuto Switched off heating system switched on On heating system switched off Off AUTO MANU automatic mode AUTO manual mode MANU Sig x determines the signal level in the position of the module wher...

Страница 16: ...hin two days and then will automatically switch on the heating the necessary amount of time in advance The time of advance start up is automatically limited to 2 hours EXPLANATION OF HYSTERESIS CONST...

Страница 17: ...h the basic requirements and other relevant provisions of directive 1999 5 ES Issued 22 04 2008 If in warranty or post warranty service is required send the unit to the manufacturer s address WARRANTY...

Отзывы: