background image

12

12

ENGLISH

1. INTRODUCTION

This instruction manual has been drafted 

in accordance with the requirements of the 

Machinery Directive CE 2006/42/EG. The 

instruction manual is an integral part of the 

lifting tower to be consulted before, during 

and after tower’s start-up, likewise whenever 

deemed necessary, respecting the contents 

for each and all the parts thereof.

This is the only way to achieve the basic ob-

jectives established in the manual’s base such 

as preventing accident risks and the maxi-

mum possible optimisation for the lifting 

tower features.

This manual has taken extreme care regar-

ding safety and accident prevention at work 

while using the machine, highlighting infor-

mation of particular interest to the user.

ATTENTION: BEFORE TO USING THE 

LIFTING TOWER, 

READ THIS MANUAL CAREFULLY

2. GENERAL DATA
2.1. Technical Data:
Name:

 LIFTING TOWER

Model

: AT-04B

Technical characteristics:

Maximum height: 5,00m.

Minimum height: 1,59m.

Maximum load: 200kg.

Minimum load: 25kg.

Material: Aluminium AL Si 6082 / T6.

Workspace: 1,45 x 1,49m.

Closed base area: 0,38 x 0,48m.

Weight: 93kg.

Winch: 500kg maximum load with automa-

tic load retention brake.

Cable: Galvanized steel under EN 12385-4.  

Cable maximum load: 956kg.

Cable torsion resistance: 1.770N/mm².

Cable diameter: 4mm.

Cable composition: 7x19+0.

Fixation of tower sections to working height 

with safety pins.

Leg anchorage with safety pins.

Bubble level to adjust tower’s vertical posi-

tion.

Equipment description:

Lifting tower AT-04B has been designed to 

vertically raise structures and lighting and 

sound equipment to different heights.

Tested by skilled personnel having passed all 

the operating, maximum load and dimen-

sion inspections.

Company:

 FENIX Stage, S.L.U. 

Address:

 Avda. de los Trabajadores, 24

Horno de Alcedo - 46026 - Valencia (Spain)

2.2. Applicable regulations

- Machinery Directive CE 2006/42/EG.

- BGV C1 (GUV 6.175).

- BGG 912 (GUV 66.15, GUV G-912).

- EN 12385-4:2008-06.

- DIN EN 10305-3:2010-05.

Содержание AT-04B

Страница 1: ...erie Serial No Instrucciones Instructions Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixs...

Страница 2: ...2 2 FENIX STAGE S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain...

Страница 3: ...liability the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and autho...

Страница 4: ...sions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusiones Conclusions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusio...

Страница 5: ...p g 8 seguir las instrucciones de uso ver punto 4 p g 9 un manteniminto peri dico ver punto 5 p g 10 conocer los sistemas de prevenci n ver punto 7 p g 11 BGV C1 is a regulation for staging and pro d...

Страница 6: ...E SEGURIDAD 8 4 INSTRUCCIONES DE USO 9 5 MANTENIMIENTO 10 6 RIESGOS ESPEC FICOS 10 7 SISTEMAS DE PREVENCI N 11 INDEX 1 INTRODUCTION 12 2 GENERAL DATA 12 2 1 Technical data 12 2 2 Applicable regulation...

Страница 7: ...naci n TORRE ELEVADORA Modelo AT 04B Caracter sticas t cnicas Altura m xima 5 00m Altura m nima 1 59m Carga m xima 200kg Carga m nima 25kg Material Aluminio seg n AL Si 6082 T6 rea de la base abierta...

Страница 8: ...elevadora ni apoyarlas en l para realizar ning n tipo de trabajo Tenga cuidado con todo tipo de salientes por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importa...

Страница 9: ...ga Ver fig 3 p g 17 7 Elevaci n Para elevar los perfiles hay que seguir un orden concreto El primer perfil que hay que subir siempre ser el m s aleja do del cabestrante Liberar el gatillo de segu rida...

Страница 10: ...os de carga E en posici n vertical y bajar el ca rro X girando la manivela del cabestrante B ejerciendo un poco de presi n sobre el carro X Meter las patas H en su sopor te para transporte C ajustando...

Страница 11: ...N Sobre fallo del sistema de freno Disponer de cabestrante conforme a las nor mas mencionadas en la directiva de seguri dad BGV C1 especialmente DIN EN ISO 12100 2011 03 y DIN EN ISO 12100 1 2004 04 S...

Страница 12: ...AT 04B Technical characteristics Maximum height 5 00m Minimum height 1 59m Maximum load 200kg Minimum load 25kg Material Aluminium AL Si 6082 T6 Workspace 1 45 x 1 49m Closed base area 0 38 x 0 48m W...

Страница 13: ...lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous signs etc It is very important to avoid the presence of...

Страница 14: ...loading instructions See fig 3 page 17 7 Elevation To lift the profiles a specific or der must be followed The first profile to be raised will always be the one located furthest from the winch Release...

Страница 15: ...he safety pins A in closed position S Move the forklifts E in vertical position and lower the carriage X by turning the winch handle B and pressing down a little on the carriage X Place the outriggers...

Страница 16: ...tions metioned in the BGV C1 directive spe cially DIN EN ISO 12100 2011 03 and DIN EN ISO 12100 1 2004 04 About loss of stability Maintenance of lifting tower stability must basically be as per the f...

Страница 17: ...17 Distancia Distance Carga m xima Maximum load 20cm 200kg 45cm 160kg Distancia del centro de la carga a la torre Distance from the center of the load to the tower Figura 2 Figura 3 20cm 45cm...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ......

Страница 23: ...23 NOTAS NOTES LIFTING TOWERS...

Страница 24: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Отзывы: