Notes:
1)
Touch screen can work at a minimum exterior temperature of -20ºC.
2)
Temperature and relative humidity range are shown in the figure below. Wet bulb temperature should be 60°C Max, and no
condensation of water.
fig 1.
Temperature and relative humidity for OP12TS
.
3)
℃
Temperature and relative humidity range are shown in the figure below. Wet bulb temperature should be 39
max. and
no condensation of water.
fig 2.
Temperature and relative humidity for OP15TS, OP17TS and OP19TS
2.3.
Electrical Characteristics
OP12TS
OP15TS
OP17TS
OP19TS
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Power Consumption (W)
-
6.78 8.42
-
10.9 12.76
-
21.1 23.4
-
23.98 26.56
Note:
The specified power consumption are under 25 ºC. Mosaic(black & white) pattern is displayed. The used lamp current is the
lamp typical current (P
BL
= V
BL
x I
BL
x N
Lamp
).
20/35
E
N
G
L
IS
H
Содержание OP Series
Страница 27: ...OP15TS fig 12 Fixing holes and window for OP15TS kiosk mounting All dimensions are in mm 27 35 ENGLISH...
Страница 28: ...OP17TS fig 13 Fixing holes and window for OP17TS kiosk mounting All dimensions are in mm 28 35 ENGLISH...
Страница 29: ...OP19TS fig 14 Fixing holes and window for OP19TS kiosk mounting All dimensions are in mm 29 35 ENGLISH...
Страница 33: ...fig 17 Mechanical dimensions of OP17TS series touch panels All dimensions are in mm 33 35 ENGLISH...