2.4.
Optical Specifications
The test of Optical specifications shall be measured in a dark room (ambient luminance ≤ 1 lux and
temperature = 25±2
℃
) and test unit shall be located at an approximate distance 50cm from the LCD surface
at a viewing angle of θ and Φ equal to 0°. While scanning θ and/or Ø, the center of the measuring spot on the
Display surface shall stay fixed. The measurement shall be executed after 30 minutes warm-up period.
Optimum viewing angle direction is 6 ’clock.
OP12TS
OP15TS
OP17TS
OP19TS
Parameter
Symbo
l
Condition
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
Viewing
Angle range
x axis, right(
Φ
=0º )
Θ
r
CR > 10
60
65
-
65
75
-
70
80
-
70
80
-
Deg.
x axis, left (
Φ
=180º )
Θ
l
60
65
-
65
75
-
70
80
-
70
80
-
Deg.
y axis, up (
Φ
=90 º)
Θ
u
45
50
-
60
70
-
60
75
-
60
75
-
Deg.
y axis, down (
Φ
=270
º)
Θ
d
55
60
-
50
60
-
70
85
-
70
85
-
Deg.
Viewing
Angle range
x axis, right(
Φ
=0º )
Θ
r
CR > 5
-
-
-
70
80
-
75
88
-
75
88
-
Deg.
x axis, left (
Φ
=180º )
Θ
l
-
-
-
70
80
-
75
88
-
75
88
-
Deg.
y axis, up (
Φ
=90 º)
Θ
u
-
-
-
70
80
-
70
85
-
70
85
-
Deg.
y axis, down (
Φ
=270
º)
Θ
d
-
-
-
70
80
-
70
85
-
70
85
-
Deg.
Luminance Contrast ratio
CR
Θ
= 0°
(Center)
Normal
Viewing
Angle
400
500
-
400
500
-
500
800
-
500
800
-
Luminance of White
Yw
300
400
-
200
250
-
250
300
-
250
300
-
cd/m2
White luminance uniformity
∆
Y
55
75
75
80
-
75
-
-
75
-
-
%
Reproduction
of color
White
Wx
0.310
0.340
0.370
0.283
0.313
0.343
0.283
0.313
0.343
Typ
-0.03
0.313
Typ
+0.03
±0.03
Wy
0.316
0.346
0.376
0.299
0.329
0.359
0.299
0.329
0.359
0.329
±0.03
Red
Rx
0.571
0.601
0.631
0.616
0.646
0.676
0.605
0.635
0.665
0.639
Ry
0.314
0.344
0.374
0.313
0.343
0.373
0.312
0.342
0.372
0.342
Green
Gx
0.302
0.332
0.362
0.281
0.311
0.343
0.268
0.298
0.328
0.297
Gy
0.508
0.538
0.568
0.547
0.577
0.607
0.581
0.611
0.641
0.615
Blue
Bx
0.117
0.147
0.177
0.118
0.148
0.178
0.117
0.147
0.177
0.146
By
0.143
0.173
0.203
0.090
0.120
0.150
0.040
0.070
0.100
0.068
Response
Time
Rising
Tr
-
10
20
-
2
4
-
1.2
2.4
-
1.3
2.6
ms
Falling
Tf
-
15
30
-
6
8
-
3.8
7.6
-
3.7
7.4
ms
Cross Talk
CT
-
-
-
-
2.0
-
-
1.5
-
-
-
%
Notes:
5.
Viewing angle is the angle at which the contrast ratio is greater than 10. The viewing are determined for the horizontal
or 3, 9 o’clock direction and the vertical or 6, 12 o’clock direction with respect to the optical axis which is normal to
the LCD surface.
6.
Contrast measurements shall be made at viewing angle of θ= 0° and at the center of the LCD surface. Luminance shall
be measured with all pixels in the view field set first to white, then to the dark (black) state. Luminance Contrast Ratio
(CR) is defined mathematically:
CR =Luminance when displaying a white raster/Luminance when displaying a black raster
7.
The White luminance uniformity on LCD surface is then expressed as:
∆Y = ( Minimum Luminance of 9points / Maximum Luminance of 9points ) * 100
8.
Cross-Talk of one area of the LCD surface by another shall be measured by comparing the luminance (YA) of a
25mm diameter area, with all display pixels set to a gray level, to the luminance (YB) of that same area when any
adjacent area is driven dark.
2.5.
Touch Screen Specification
Parameter
Resolution
4096 x 4096
Touch activation force
Less than 100g (adjust allowed)
Durability
Scratch-free;More than 50,000,000 touches in one location without failure.
21/35
E
N
G
L
IS
H
E
N
G
L
IS
H
E
N
G
L
IS
H
Содержание OP Series
Страница 27: ...OP15TS fig 12 Fixing holes and window for OP15TS kiosk mounting All dimensions are in mm 27 35 ENGLISH...
Страница 28: ...OP17TS fig 13 Fixing holes and window for OP17TS kiosk mounting All dimensions are in mm 28 35 ENGLISH...
Страница 29: ...OP19TS fig 14 Fixing holes and window for OP19TS kiosk mounting All dimensions are in mm 29 35 ENGLISH...
Страница 33: ...fig 17 Mechanical dimensions of OP17TS series touch panels All dimensions are in mm 33 35 ENGLISH...