User’s Manual Series TAS-1

FEMA ELECTRÓNICA - Page 3

1.2- IF THIS IS THE FIRST TIME YOU WORK WITH A TAS-1 METER...

TAS-1 Rear View

TAS-1 Frontal View

Status Led for

alarms 1,2,3 and 4

Leypad Function Led

Red Led - keypad acting as number

Green Led - keypad acting as direct access

6 pads for programming

double function

Indication

5 displays 7 segments

U n i t s

Activity Led

Decimal

Point

Connector for PC

Configuration

(PCConnector

cable needed)

Power

Input Signal

(3 or 4 pole Terminal

depending on the

unit)

(N)

(+)

(L)

(-)

Relay  1

Output

Relay 2

Output

Output for Optional

Boards

(See  pages 10 to 14)

Note .- The 2 relay outputs and the Optional Boards are
OPTIONAL and are NOT INCLUDED with the basic unit.

1.3- FRONTAL VIEW AND REAR VIEW

We strongly recommend you to read the following
paragraphs. Following ideas need to be clearly understood
in order to easily adjust and program the unit.

WHEN POWERING THE INSTRUMENT the meter displays
a message indicating the configured signal input range (see
page 4).

IF THE TAS-1 DETECTS A STRANGE SITUATION on the
instrument status, or sensor break, etc, the instrument will
show an error message (see page 8 «messages and
errors»).

THE FRONTAL KEYPAD is composed of 5 function/key
pads and 1 programming pad. The pads have two functions,
acting both as number keys (when a number needs to be
entered) and as direct access keys to the following
functions :

Key AL

-

Access to the ALARM setpoints

Key HI

-

Value for the HIGH Indication

Key LO

-

Value for the LOWIndication

Key ADJ

-

Access to the automatic «on the

field» offset correction and High Level
Input Signal correction

Key DP

-

Decimal Point Position

K e y   P R O G   -  A l l o w s   t h e   i n t r o d u c t i o n   o f   t h e

PROGRAMMING codes (4 digit
codes, as shown on page 4). These
codes, when validated, activate
different input signal modes, and
advanced configurations for alarms,
indication, etc.

«TIME» MESSAGE .- If while introducing a programming
code or while reconfiguring the unit parameters (such as
the alarm setpoints or others) the user does not interact
with the unit for a period of 5 seconds, the TAS-1 will show
the message «TIME», cancel the ongoing changes, and
roll-back to the previous configuration. This is a security
function which disables the situation where a unit would be
«hanged» for a long time waiting for the operator to finish a
programming.

THE TAS-1 UNITS ARE FULLY CONFIGURABLE. The unit
is 100% configurable from the frontal keypad. The
programming software also allows an easy configuration
from a PC 

(PCConnection Cable needed)

.

OPTIONS .- This manual includes description and operating
instructions for the basic unit and the additional extra
options accepted. These options include Relay Output
Contacts, Analog Outputs, RS485 Outputs, Peak/Valley
memory, etc. If your instrument does not include these
options, they can easily be added.

SIGNAL INPUT RANGES .- To work with an input signal
range not indicated in this manual, select the closest input
signal range accepted, and change the input/indication
parameters with the code 14 11 (see later in this manual).
For example, to configure a 0/60 mV input coming from a
10 Amper shunt, we need to :

1.- select the 0/100 mV input signal range
2.- enter on code 14 11 for Editing Adjustments
3.- edit 0=0 and 60=10.000

If later on we need to change the 10.000 value for any other
value we can do it directly with the keypad HI.

Содержание TAS-1-IAC

Страница 1: ...CA Page 1 FEMA ELECTR NICA INTELLIGENT PANEL METERS Series TAS 1 Intelligent Panel Meters info fema es www fema es USER S MANUAL AC Current DC Current AC Voltages DC Voltages TAS 1 IAC TAS 1 IDC TAS 1...

Страница 2: ...ration 6 4 6 Manual Adjustment 7 4 7 Dealing with Errors 7 4 8 Advanced Indication 7 4 9 Blocking the Keypad 7 4 10 Resetting the system Default values 7 4 11 Messages and Errors 8 5 Configuring with...

Страница 3: ...Level Input Signal correction Key DP Decimal Point Position Key PROG Allows the introduction of the PROGRAMMING codes 4 digit codes as shown on page 4 These codes when validated activate different inp...

Страница 4: ...t 14 14 INPUT ONERR OFF ON 1 1 Visualization 14 13 DISPLAY NULL LAST 1 1 ON OFF 1 1 OFF ON 3 2 1 FIL 2 FIL 3 FIL 1 FILT A D Q N AVERA REAL 1 1 INPUT STEP XXXXX Alarm 1 Alarm 2 Alarm 3 Alarm 4 13 11 AL...

Страница 5: ...ion XXXX X 1 Press DP 2 message DP during 1 second Press 2 to fix decimal point position 2 To fix at other positions press 1 2 3 4 or 5 3 Validate changes pressinf message INPUT shows the configuratio...

Страница 6: ...m activation The hysteresis points are defined on parameter HYST for each alarm Security Mode activated on alarms acting as minimum Securty Mode deactivated Output relay are inactive until the set poi...

Страница 7: ...Code 14 11 Function Code 14 22 Function Resets the unit to the default manufacturing values It is needed to reconfirm the action by pressing INTRO after the message Acquisition Mode Real STEPValue 10...

Страница 8: ...recovers the normal working state when situation clears Errors Errors are associated with critical situtations which disable the hability to measure the signal The error remains active on display unt...

Страница 9: ...tion 32 000 points ENVIRONMENTAL DATA Working Temperature 0 50 C Storage Temperature 20 85 C Humidity 0 85 non condensaded MECAHNICALDATA Dimensions Standard 1 8 DIN 96 x 48 x 124 mm 3 78 x 1 89 x 4 8...

Страница 10: ...ot need to be readjusted most of the times in case of trouble with the input signal such as loop break or sensor break the analog output signal will exhibit always the same behaviour predefined by the...

Страница 11: ...essage ERROR Informs that at least one of the values is not correct and the whole configuration could not be applied Repeat the process from the begining 7 2 INSTALLING THE OPTION BOARDS The Option Bo...

Страница 12: ...mposed of 1 4 bits b0 0 Value contained on register 00 00H is an indication number b0 1 Value contained on register 00 00H is not an indication Word b4 b3 b2 b1 0 Reserved 3 Ovr 6 Con 9 MErr1 12 Reser...

Страница 13: ...acion MASTER and SLAVE ADDRESS 1 CHARACTER Instrument Address FUNCTION 1 CHARACTER Function 04H register read READING STARTREGISTER 2 CHARACTERS Register 00 00H Display Value NUMBER OF REGISTERS TO RE...

Страница 14: ...tering the Menu Introduce the programming code 14 23 Message E INP TEK board recognized Configuring the external contacts Parameter INP_1 Contact 1 ON Active OFF NotActive Parameter FUN_T Function ass...

Страница 15: ...unit to control a machine or process where injury to personnel or damage to equipment or process may occur as a result of failure of the unit External Protection Fuse to be added for 230 Vac 80mA fuse...

Страница 16: ...YS COUNTERS PROCESS SIGNALS TEMPERATURES TACHOMETERS SERIAL RSREPEATERS CLOCKS CHRONOMETERS PANEL METERS AC ELECTRICAL SIGNALS DC ELECTRICAL SIGNALS TEMPERATURES LOADCELLS PROCESS SIGNALS TACHOMETERS...

Отзывы: