FEIG ID CPR60 Скачать руководство пользователя страница 2

IDENTIFICATION 

ID CPR60 

Note 

 

 

 

Page 2 of 22 

 

 

 

Note 

Note 

© Copyright 2022 by 
 
 

FEIG ELECTRONIC GmbH 

 

Industriestraße 1a 

 

D-35781 Weilburg (Germany) 

 

Tel.: +49 6471 3109-0 

 
 

https://www.feig.de/en/

 

 

[email protected]  

 

 

With the edition of this document, all previous editions become void. Indications made in this manual may be 
changed without previous notice. 

Copying of this document and giving it to others and the use or communication of the contents thereof are 
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved 
in the event of the grant of a patent or the registration of a utility model or design. 

Composition of the information in this document has been done to the best of our knowledge. 
FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this 
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, 
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. 

The instructions given in this manual are based on advantageous boundary conditions. 
FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments 
and does not give any guarantee for the functionality of the complete system which incorporates the subject 
of this document. 

FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not 
designed with components and testing methods for a level of reliability suitable for use in or in connection 
with surgical implants or as critical components in any life support systems whose failure to perform can 
reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the 
user or application designer must take reasonably prudent steps to protect against system failures. 

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this 
document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH 
does not convey any license under its patent rights nor the rights of others. 

 

 

Содержание ID CPR60

Страница 1: ...IDENTIFICATION M91210 3e ID B Ende der Liste f r Textm arke Deckbl att INSTALLATION MANUAL ID CPR60 RFID Reader Module Model Article No ID CPR60 A 5491 000 00...

Страница 2: ...y not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guara...

Страница 3: ...6 2 3 Development Board 6 3 Dimensions 7 4 Installation and wiring 8 4 1 Connector X1 8 4 2 Connector ANT 11 5 Standby Low Power Card Detection 12 6 Technical Data 13 7 Radio Approvals 15 7 1 Declara...

Страница 4: ...ce or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use...

Страница 5: ...nown CPR family like the reader module ID CPR74 or the wall mount reader ID CPR50 10 and is compatible with them mainly The use of ISOHost commands guarantees an easy creation of user software as well...

Страница 6: ...and antenna is available on request see Available Accessories The ID CPR60 DevBoard offers 3 SAM sockets for ID 000 smart cards 1 smart card connector for full size ID 1 cards and different connectors...

Страница 7: ...N ID CPR60 Page 7 of 22 3 Dimensions The ID CPR60 reader module has been designed for the integration into terminals printers or handheld devices and so on Figure 1 Dimension Top View Figure 2 Dimensi...

Страница 8: ...following table shows the pin assignment of the connector Interfaces and functions are described from the ID CPR60 view an input must be connected to one output or vice versa Figure 3 Connector X1 At...

Страница 9: ...K SAM4 18 n c 19 SAM1_I O 20 n c 21 SAM2_I O 22 n c 23 SAM3_I O 24 n c 25 KCC_I O SAM4 26 SAM1_VCC 27 n c 28 SAM2_VCC 29 n c 30 SAM3_VCC 31 n c 32 GND 33 n c 34 KCC_VCC SAM 4 35 GND 36 SAM1_CLK 37 SPI...

Страница 10: ...M 4 54 n c 55 GND 56 n c 57 n c 58 GND 59 n c 60 5 V DC Supply 61 n c 62 n c 63 n c 64 nRESET Reset Input 65 RS232_TxD reader TxD host RxD 66 RS232_RxD Reader RxD Host TxD 67 n c 68 n c 69 n c 70 n c...

Страница 11: ...escription and hints for building external 50 antennas can be taken from the application note N20901 d ID B pdf NOTICE Only for use with 50 matched external antennas The permanent usage of unmatched a...

Страница 12: ...y mode is activated if input nLOW_PWR is set to low In this mode the reader wakes up if a contactless card is detected in front of the RFID antenna or if the Input nKCC_DET is set to 0 The reader rema...

Страница 13: ...sumption 400 mA without SAM 25mA Standby mode 50mA Standby Mode with Wake Up by Card Interfaces USB Full Speed 12 Mbit s Self Powered Device SPI Slave Device up to 16 Mbit s RS232 LVTTL 4 800 921 600...

Страница 14: ...Power Class A B C Operating Modes ISOHost Mode Polling Mode Radio Approval Europe UK USA Canada EN 300 330 EN 300 330 FCC Title 47 CFR Part 15 RSS 210 Issue 10 RSS Gen Issue 5 incl Amendment 1 EMV EN...

Страница 15: ...ty is available at the following internet address https www feig de en service eu declarations of conformity 7 2 Declaration of Conformity UKCA UKCA Declaration of Conformity Hereby FEIG ELECTRONIC Gm...

Страница 16: ...toris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susc...

Страница 17: ...ystem must be professionally installed to ensure compliance with the Part 15 certification IC certification It is the responsibility of the operator and professional installer to ensure that only cert...

Страница 18: ...IDENTIFICATION ID CPR60 Page 18 of 22 8 ANNEX 8 1 Annex A ID CPR60 DevBoard Reference Design Figure 5 Top Overlay Print Figure 6 Top Layer...

Страница 19: ...IDENTIFICATION ID CPR60 Page 19 of 22 Figure 7 Bottom Layer...

Страница 20: ...IDENTIFICATION ID CPR60 Page 20 of 22 Figure 8 CPR60 DevBoard Schematic Part 1...

Страница 21: ...IDENTIFICATION ID CPR60 Page 21 of 22 Figure 9 CPR60 DevBoard Schematic Part 2...

Страница 22: ...Horizontal J8 Pin header 5 poles RM2 54 Horizontal KCC SAM 4 SMD Smart Card Connector ID1 8 Pin R1 SMD resistor 100K0 0 125W R16 SMD resistor 220R0 0 125W R17 SMD resistor 100R0 0 125W R3 R4 R11 R12 R...

Отзывы: