![Feig Electronic ID LRU500i-BD Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/feig-electronic/id-lru500i-bd-series/id-lru500i-bd-series_installation-manual_3916159023.webp)
IDENTIFICATION
ID LRU500i
5 Terminals
Installation
Page 23 of 35
5.9 USB Mini Interface on Connector X6
The reader is equipped with an integrated USB on-the-go interface. This can be used either to connect the
reader to a host system or, by means of a special on-the-go adapter cable, for connection of a USB memory
stick to the reader. In both cases, the connection is carried out via terminal X6. The pinout is standardized.
A standard shielded USB cable can be used to connect the reader to a host system. The data rate of the
reader is limited to 12 Mbit (USB full speed).
NOTE:
The length of the USB cable must not exceed 5 m (200 inch). It is not allowed to use longer cables.
5.9.1 USB Flash Drive Service Functions
Via an optionally available USB On-The-Go adapter cable, the interface can be converted to a USB host
interface. The adapter cable allows the connection of a USB memory stick to the reader. The USB memory
stick can be used to carry out various service functions, such as reading log and service data and uploading
a configuration file.
5.9.2 Reading of Log and Service Data
When connecting the USB flash drive during a running operation, the reader will create a subdirectory in the
root directory named after the device ID of the connected reader (see label on the back side of the reader)
and store device information such as firmware status and IP address in the INFO.LOG file within this
directory. If a corresponding file already exists for this reader the file will be updated with the new information
and the current date and time.
Fig. 19: USB Mini interface for host communication
Fig. 20: USB On-The-Go adapter cable