IDENTIFICATION
ID LRU500i
5 Terminals
Installation
Page 21 of 35
CAUTION:
•
The relay outputs are designed for max. 24 V DC / 2 A continuous load.
•
The maximum switching current must not exceed 1 A.
•
The relay outputs are intended for switching resistive loads only. In case an inductive load is
connected, the relay contacts must be protected by an external protective circuit.
5.8 Digital Inputs on Connector X5
There are 2 digital inputs available on X5. The optocouplers on X5 are galvanically isolated from the reader
electronics and must therefore be supplied with an external voltage.
Fig. 17: Connector X5 pin assignment for digital inputs
Fig. 16: Connector X4 pin assignment for relay outputs (version LRU500i-BD)