11.1.
EPC Class 1 Commands
These commands support the functions of the EPC class1 Gen 2 Transponder
11.1.1. [0x18] Kill
This command kills a transpoder. It will not respond anymore to any RF command.
REQUEST-DATA
4
5
1 Byte
EPC_LNG
Bytes
1 Byte
K_PW_LNG
Bytes
0x18
MODE
EPC_LF
EPC
K_PW_LNG
K_PW
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
EPC_LF
ADR
ADR:
b000
non-addressed
b001
addressed
EPC_LF:
If this bit is set the parameter EPC_LNG must inserted into the protocol.
b1:
The protocol includes the parameter EPC_LNG. The EPC has a variable
length as defined in EPC_LNG.
EPC_LNG:
Is a optional parameter and depends on the setting of EPC_LF (see MODE). EPC_LNG
defines the length of the following EPC field.
EPC:
EPC of the Transponder. The EPC is required only in the addressed mode.
K_PW_LNG:
Length of Kill Password.
K-PW:
Kill Password.