IDLE-FLASH / ACTIV-FLASH: (DigitalIO.Signaler….…FlashFrequency)
By means of the two bytes "IDLE-FLASH" and "ACTIV-FLASH" the signal transmitter may be
provided with a flashing frequency for idle and active position.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
RED
BLUE
GRN
Bit combination
flashing frequency
b11
b10
b01
b00
1 Hz
2 Hz
4 Hz
8 Hz
ACTIV-xxx-TIME (DigitalIO.Signaler……..ActivationTime)
If a Transponder was detected, the transmitter and the duration can be set by the bytes ACTIV-
STATE and ACTIV-FLASH. Each signal transmitter (LED) may be activated temporarily limited.
Signal transmitter
time range
ACTIV-GRN-TIME
0...255 x 100 ms
ACTIV-BLUE-TIME
0...255 x 100 ms
ACTIV-RED-TIME
0...255 x 100 ms
NOTE:
LED green and LED red are blinking alternately if a read error of the EEPROM occurred. Af-
ter power-up or a
9.3. [0x63] RF Controller Reset
command all LEDs are blinking for 2 se-
conds
7.3.1. Dedicated Input / Output Functions
LED
Color
Dedicated Function
1
red
1. The Reader is initializing after power up or a
2. 1 second blink.
3. Alternately blink with green LED after an EEPROM error.
2
green
1. The Reader is initializing after power up or a
2. Alternately blink with red LED after an EEPROM error.
2
blue
1. The Reader is initializing after power up or a
2. The RF interface has a faultless communication with a Tran-
sponder.