7.5. CFG11: Read Mode – Read Data
The parameters of the CFG11 configuration block contain Scan Mode settings. To enable Scan
Mode the Scan bit in the READER-MODE register of the configuration block
Byte
0
1
2
3
4
5
6
Contents TR-DATA-1
TR-DATA-2
TR-DATA-3
BANK
DB-ADR
0
Default
0x21
0x00
0x00
0x00
0x0000
Byte
7
8
9
10
11
12
13
Contents
DB-N
D-START
D-LGT
Default
0x0001
0x0004
TR-DATA-1
1 2
:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
Exten-
sion
0
0
ANT
Byte
Order
DB
0
DB
SNR
SNR: (OperatingMode.ScanMode.DataSelector.UID)
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB: (OperatingMode.ScanMode.DataSelector.Data)
b0:
no data block will be stored
b1:
data block will be stored
Byte Order DB: (OperatingMode.ScanMode.DataSource.ByteOrderOfData)
b0:
MSB first
b1:
LSB first
ANT
:
(OperatingMode.ScanMode.DataSelector.AntennaNo)
b0:
the number of the antenna will not be stored
b1:
the number of the antenna (1-2) where the Transponder has been de-
tected, will be stored.
Extension
:
If this flag is set TR-DATA-2 is present
3
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-