7.13. CFG36: RF-Interface UHF
The parameters of the CFG36 configuration block contain global Transponder drivers and Reader
settings for UHF.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
UHF-Power
REG
0x00
0x00
0x00
Default
0x0010
0x00
0x06
Byte
7
8
9
10
11
12
13
Contents
0x00
FREQ_US
0x00
Nr Prefered
Chn
Prefered Chn
Default
0x3201
0x04
0x4A7D
TAG-DRV
1
: (Transponder.Driver.UHF.Drivers)
Defines the Transponder types that are operated by the Reader.
Byte:
0
1
Bit:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
0
0
0
0
0
E
0
0
0
0
b0
⇒
Driver for the Transponder type is inactive
b1
⇒
Driver for the Transponder type is active
.E: (Transponder.Driver.UHF.EPC_Class1Gen2)
EPC class 1 Gen 2
In principle, only those Transponder drivers should be active that are used in the
actual application. Thus, the reaction time of the Reader for Transponder read- /
write-operations is reduced and the danger of a parasitic Transponder access is
minimized.
UHF-Power:
0x00: Full Power
0x01: Medium Power
0x02: Low Power
REG:
0x04 = FCC
902 MHz – 928 MHz
0x06 = EN 302208
865 MHz – 868 MHz
5
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].