OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 36 of 96
H90701-3e-ID-B
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
BANK_NR
BANK_NR: (OperatingMode.ScanMode.DataSource.BankNo)
In case of Class 1 Gen 2 Transponder BANK_NR is defined as follows:
b00
reserved
b01
EPC memory bank
b10
TID memory bank
b11
User memory bank
NOTE:
EPC Gen 2 memory banks can only be read in open state.
DB-ADR
1
: (OperatingMode.ScanMode.DataSource.FirstDataBlock)
0x00...0xFF
Address of first data block. Range: 0x00...0xFF.
DB-N
: (OperatingMode.ScanMode.DataSource.NoOfDataBlocks)
Number of data blocks. Range: 0x01...0x20.
D-START: (OperatingMode.ScanMode.DataSource.FirstByte)
This parameter defines the first byte in the raw data (defined by DB-ADR and D-LGT),
which will be transferred in Scan-Mode. To transfer the whole data block D-START must be
set to 0.
NOTE:
The size of one data block depends on the type of Transponder.
4
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = [0x11].