background image

OBID

 

i-scan

 ® 

UHF 

Installation 

ID ISC.LRU3000/3500 

 

FEIG ELECTRONIC GmbH 

Page 23 of 32 

M21016-3e-ID-B 

 

 

 

 

 

Green 

Yellow 

Red 

Description 

Configurations-Reset: 

FLASH 

FLASH 

FLASH 

While T1 is pushed and hold for maximal 5s 

(light in sequence) 

ON 

ON 

ON 

After T1 has been pushed and hold for 5s. Configuration 

Reset has been finished.  

 

 

 

 

Input / Output LED (yellow):

 

Configurable LED. 

Can display the status of a digital input or output 

 

 

ANT 1 – 4:

 

Green 

HF Power switched on 

Blue 

Tag-Detect 

Red 

Antenna impedance error (> 50Ohm or <50Ohm) 

 

5.2. Reset Push Buttons 

Figure 19 shows the position of the reset push button’s T1 and T2.  

At the right side of the connector X6 the push button T2 is positioned. With this push button a CPU-
Reset can be performed. 

With the push button T1 within the reader housing on left side of X3 a complete con-

figuration reset can be performed. For performing a reset you should use a pa-
per clip and push the button T1 for at least 5 s until the 3 status LED’s (left 

side) are switched on continuously, see 5.1. Status LEDs 

Table 12: Configuration of the LEDs 

 

Table 12: Configuration of the LEDs 

 

Figure 19: Position of the reset-switches T1 and T2 

Содержание ID ISC.LRU3500-EU

Страница 1: ...Date 2012 06 11 Vers no 1 12 m dudde hochfrequenz technik Rottland 5a D 51429 Bergisch Gladbach Germany Tel 49 2207 96890 Fax 49 2207 968920 Annex no 5 Functional Description User Manual...

Страница 2: ...INSTALLATION final public B 2013 10 28 M21016 3e ID B ID ISC LRU3000 ID ISC LRU3500 UHF Long Range Reader...

Страница 3: ...this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use...

Страница 4: ...er issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this ma...

Страница 5: ...connection X1 11 4 2 2 Power Supply via Power over Ethernet PoE 12 4 3 Interfaces 13 4 3 1 Ethernet Interface on connector X2 13 4 3 2 USB Interface on connector X3 13 4 3 3 USB Interface on connector...

Страница 6: ...ng to EN302 208 24 5 3 2 FCC Reader according to FCC 47 Part 15 25 6 Technical Data 26 7 Radio Approvals 29 7 1 Europe CE 29 7 2 Declaration of Conformity Directive 1999 5 EC R TTE 30 7 3 USA FCC and...

Страница 7: ...inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation op...

Страница 8: ...Reader type Description ID ISC LRU3500 EU Device version for Europe with PoE max 4Watt ID ISC LRU3000 EU Device version for Europe without PoE max 2Watt ID ISC LRU3500 FCC Device version for USA with...

Страница 9: ...016 3e ID B 3 Installation The Reader is designed for wall mount including outdoors Holes for mounting on a wall are provided in the housing It is not necessary to open the reader housing mounting 261...

Страница 10: ...ion shows the available push buttons X2 X3 X4 X5 X6 T1 T2 X1 ANT1 ANT2 ANT3 ANT4 Figure 2 Connection Overview Table 3 Connection terminals Connector Description ANT 1 4 Connection of the external ante...

Страница 11: ...torque for the SMA sockets is 0 45 Nm 4 0 lbf in CAUTION Exceeding the tightening torque will destroy the plug Table 5 External antenna connection Terminal Description ANT 1 4 Connection for external...

Страница 12: ...DC 5 X1 Pin 2 GND Ground supply voltage Figure 4 Connection for the power supply CAUTION The reader has to be supplied by a limited power supply e g NEC Class 2 LPS power sup ply according IEC EN 6095...

Страница 13: ...PoE is used cable cross section CAT5 7 Maximum cable length for PoE 0 4mm 30m 0 6mm 70m For detailed technical information regarding the 802 3at standard please refer to the most recent edition of th...

Страница 14: ...each device has a unique address on the net work All Readers have a factory set IP address Table 8 Standard factory configuration of the Ethernet connection Network Address IP Adresse 192 168 10 10 Su...

Страница 15: ...es an overview about successfully tested Wireless LAN Sticks Table 9 Successfully tested WLAN Sticks Manufacturer Description Model Buffalo Wireless N NFiniti High Power WLI UC G300HP Buffalo Wireless...

Страница 16: ...e RS485 Schnittstelle X6 4 3 5 RS485 Interface on connector X6 The connection of the RS485 interface take place via the X6 connector as well The interface pa rameter can be configured via software pro...

Страница 17: ...er A potential termination of the interface bus can be configured by the software as well NOTE Since all Readers are factory set with address 0 they must be connected and configured one after the othe...

Страница 18: ...a as well as the clock need to be supplied with an external voltage The output is configured for max 24 V DC 30 mA Figure 12 Wiring Example NOTE Please consider possible limitations of the Wiegand Con...

Страница 19: ...r pin outs IN1 IN5 Figure 14 Internal and possible external wiring of the optocoupler inputs Optocoupler input X5 1 5 The input LED associated with the optocoupler is connected internally to a series...

Страница 20: ...of 5 10 V DC and an input current of max 20 mA Polarity reversal or overload on the input will destroy it 4 5 Outputs on connector X5 4 5 1 Digital outputs on connector X5 Optocoupler output X5 1 2 Th...

Страница 21: ...wiring of the optocoupler outputs OUT1 2 CAUTION The output is configured for max 24 V DC 30 mA Polarity reversal or overload on the output will destroy it The output is intended for switching resisti...

Страница 22: ...figured for max 24 V DC 2 A constant load The switching current must not exceed 1A The relay output is intended for switching resistive loads only If an inductive load is con nected the relay contacts...

Страница 23: ...ion FLASH alternat ing OFF FLASH alternat ing Firmware Activation necessary 0x17 Wrong Firmware 0x18 FLASH synchro nous OFF FLASH synchro nous RFC Hardware Error 0xF1 OFF FLASH synchro nous FLASH sync...

Страница 24: ...Antenna impedance error 50Ohm or 50Ohm 5 2 Reset Push Buttons Figure 19 shows the position of the reset push button s T1 and T2 At the right side of the connector X6 the push button T2 is positioned W...

Страница 25: ...configured output power Pout de pends on the antenna gain in dBi and the attenuation of the antenna cable If a circular polarized antenna is used the antenna gain dBic can be reduced by 3dB At a linea...

Страница 26: ...the right output power If a circular polar ized antenna is used the antenna gain G dBic can be reduced by 3dB This is the case if the FEIG standard antenna ANT U600 270 FCC is used In this configurat...

Страница 27: ...max 150 mV or Power over Ethernet min 42 5 V DC Power Consumption max 35 W Operating Frequency EU Reader FCC Reader 865 MHz to 868 MHz EN 302208 902 MHz to 928 MHz FCC47 Part15 RF Power ID ISC LRU3000...

Страница 28: ...0 6 C Upgrade Code required further transponder types possible on demand Optical Indicators 8 LEDs for operating status and diagnostics Operating System Linux 64 MB RAM 256 MB Flash Further Features A...

Страница 29: ...32 M21016 3e ID B Vibration EN 60068 2 6 10 Hz to 150 Hz 0 075 mm 1 g Shock EN 60068 2 27 Acceleration 30 g APPLICABLE STANDARDS Radio Regulation Europe USA Canada EN 302 208 FCC 47 CFR Part 15 IC RS...

Страница 30: ...M21016 3e ID B 7 Radio Approvals 7 1 Europe CE When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R TTE Directive 199...

Страница 31: ...OBID i scan UHF Installation ID ISC LRU3000 3500 FEIG ELECTRONIC GmbH Page 30 of 32 M21016 3e ID B 7 2 Declaration of Conformity Directive 1999 5 EC R TTE Figure 21 Declaration of Conformity...

Страница 32: ...o Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates u...

Страница 33: ...gory II has been approved by Industry Canada to operate with the antenna types listed below with maxi mum permission gain and required antenna impedance for each antenna type indicated Antenna types n...

Отзывы: