![Feig Electronic ID ISC.LRU3500-EU Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/feig-electronic/id-isc-lru3500-eu/id-isc-lru3500-eu_user-manual_3877448019.webp)
OBID
i-scan
®
UHF
Installation
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 18 of 32
M21016-3e-ID-B
4.4. Digital Inputs on connector X5
The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.
Figure 13: Optocoupler pin-outs IN1 – IN5
Figure 14: Internal and possible external wiring of the optocoupler inputs
Optocoupler input (X5/1-5):
The input LED associated with the optocoupler is connected internally to a series resistor of 500
Ω
.
For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means
of an additional series resistor (see
Fehler! Verweisquelle konnte nicht gefunden werden.
).
Table 11 shows the necessary external resistors for various external voltages U
ext
.