manualshive.com logo in svg
background image

IDENTIFICATION 

 

 

M21015-4e-ID-B 

 

 

 

 

 

 

Installation 

ID ISC.LRU3000 / ID ISC.LRU3500 

UHF Long Range Reader 

 

Содержание ID ISC.LRU3000

Страница 1: ...IDENTIFICATION M21015 4e ID B Installation ID ISC LRU3000 ID ISC LRU3500 UHF Long Range Reader...

Страница 2: ...always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function...

Страница 3: ...oE 11 4 3 Interfaces 12 4 3 1 Ethernet Interface on connector X2 10 100Tbase 12 4 3 2 USB Interface on connector X3 Host Kommunikation 12 4 3 3 USB Host Interface on connector X4 13 4 3 4 RS232 Interf...

Страница 4: ...ope CE 27 7 2 USA FCC and Canada IC 28 7 2 1 USA FCC and Canada IC warning notices 28 7 2 2 Label Information 29 7 2 3 Installation with FCC IC Approval 29 7 2 4 USA FCC and Canada IC approved antenna...

Страница 5: ...the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures...

Страница 6: ...le Reader Types Reader type Description ID ISC LRU3500 EU Device version for Europe with PoE ID ISC LRU3000 EU Device version for Europe without PoE ID ISC LRU3500 FCC Device version for USA with PoE...

Страница 7: ...Installation Page 7 of 30 3 Installation The Reader is designed for wall mount including outdoors Holes for mounting on a wall are provided in the housing It is not necessary to open the reader housi...

Страница 8: ...6 T1 T2 X1 ANT1 ANT2 ANT3 ANT4 Fig 2 Connection Overview Table 3 Connection terminals Connector Description ANT 1 4 Connection of the external antennas Impedance 50 X1 Power supply 24VDC 5 X2 10 100Tb...

Страница 9: ...SMA sockets is 0 45 Nm 4 0 lbf in CAUTION Exceeding the tightening torque will destroy the plug Table 5 External antenna connection Terminal Description ANT 1 4 Connection for external antennas input...

Страница 10: ...D Ground supply voltage Fig 4 Connection for the power supply CAUTION The reader has to be supplied by a limited power supply e g NEC Class 2 LPS power supply according IEC EN 60950 1 chapter 2 5 only...

Страница 11: ...cross section CAT5 7 Maximum cable length for PoE 0 4mm 30m 0 6mm 70m For detailed technical information regarding the 802 3at standard please refer to the most recent edition of the corresponding IE...

Страница 12: ...at each device has a unique address on the network All Readers have a factory set IP address Table 8 Standard factory configuration of the Ethernet connection Network Address IP Adress 192 168 10 10 S...

Страница 13: ...e Fig 7 USB Host Interface NOTE USB Host shall not be used when the reader is powered via Power over Ethernet PoE 4 3 4 RS232 Interface on connector X6 The RS232 interface is connected on X6 The trans...

Страница 14: ...tor X6 The connection of the RS485 interface take place via the X6 connector as well The interface parameter can be configured via software protocols Fig 10 RS485 interface pin outs on X6 RS485 Interf...

Страница 15: ...hey must be connected and configured one after the other 4 3 6 Data Clock Interface on connector X5 for Scan Mode only The connection of the data clock interface take place via the digital Outputs OUT...

Страница 16: ...or max 24 V DC 30 mA Fig 12 Wiring Example NOTE Please consider possible limitations of the Wiegand Controller regarding the used supply voltage In dependency on the inner circuit of the used Wiegand...

Страница 17: ...ore be externally supplied Fig 13 Optocoupler pin outs IN1 IN5 Fig 14 Internal and possible external wiring of the optocoupler inputs Optocoupler input X5 IN1 5 The input LED associated with the optoc...

Страница 18: ...for various external voltages Uext External voltage Uext Required external series resistor Rext 5 V 10 V 11 V 15 V 270 16 V 20 V 560 21 V 24 V 820 NOTE The input is configured for a maximum input vol...

Страница 19: ...from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X5 The output must therefore be powered by an external power supply Fig 15 Optocoupler O...

Страница 20: ...put pin outs REL1 3 CAUTION The relay output is configured for max 24 V DC 2 A constant load The switching current must not exceed 1A The relay output is intended for switching resistive loads only If...

Страница 21: ...on FLASH alternatin g OFF FLASH alternatin g Firmware Activation necessary 0x17 Wrong Firmware 0x18 FLASH synchronou s OFF FLASH synchronou s RFC Hardware Error 0xF1 OFF FLASH synchronou s FLASH synch...

Страница 22: ...switched on Blue Tag Detect Red Antenna impedance error 50Ohm or 50Ohm 5 2 Reset Push Buttons Figure 19 shows the position of the reset push button s T1 and T2 At the right side of the connector X6 t...

Страница 23: ...enna is used the antenna gain dBic can be reduced by 3dB At a linear polarized antenna the maximum linear antenna gain dBi must be used POut Perp Antenna Gain Cable loss 2 1dB Correction Factor to con...

Страница 24: ...ANT U600 270 FCC is used In this configuration the maximum output power of the reader can be calculated in the following way POut 36 dBm 4 W e i r p Antenna Gain in dBi Cable Loss in dB POut 36 dBm 4...

Страница 25: ...DC 5 Noise Ripple max 150 mV 24 V DC 5 Noise Ripple max 150 mV or Power over Ethernet min 42 5 V DC Power Consumption max 35 W Operating Frequency EU Reader FCC Reader 865 MHz to 868 MHz EN 302208 902...

Страница 26: ...PC Class 1 Generation 2 ISO 18000 6 C Upgrade Code required further transponder types possible on demand Optical Indicators 8 LEDs for operating status and diagnostics Operating System Linux 64 MB RAM...

Страница 27: ...10 EMC EN 301 489 Safety Low Voltage Human Exposure EN 60950 EN 50364 7 Radio Approval 7 1 Europe CE Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC LRU3000 3500 is in compli...

Страница 28: ...the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can...

Страница 29: ...se with this device The antennas used for this transmitter must be installed to provide a separation distance of at least 23 cm from all persons and must not be located or operating in conjunction wit...

Страница 30: ...th a diameter of up to 60 mm 3309 000 00 ID ISC ANT U270 270 MS Mounting Set Antenna UHF Mounting Set for UHF Antenna ID ISC ANT U270 270 Suitable for mounting on installation pipes with a diameter of...

Отзывы: