IDENTIFICATION
ID HyWEAR compact
11 Configuration Parameters
Page 35 of 41
11.7 Button Settings
11.7.1 Unlock Trigger Button
Logical Name
DigitalIO.Button.Trigger.Enable_UnlockTrigger
Description
Defines if the scan function can be unlocked by pressing the trigger button. After unlocking, a new scan can be started.
NOTE: The scan function can be locked by the host after a scan event.
Possible Values
b0: Trigger button cannot unlock the scan
function
b1: Trigger button can unlock the scan
function
Default Value
b0
Unit
-
Reset Required
None
11.7.2 Left Button Power-Off
Logical Name
DigitalIO.Button.Left.Enable_PowerOff
Description
The device will be switched off when the left button is pressed for at least 5 seconds.
Possible Values
b0: Switch-off function disabled
b1: Switch-off function enabled
Default Value
b1
Unit
-
Reset Required
None
11.7.3 Right Button Power-Off
Logical Name
DigitalIO.Button.Right.Enable_PowerOff
Description
The device will be switched off when the right button is pressed for at least 5 seconds.
Possible Values
b0: Switch-off function disabled
b1: Switch-off function enabled
Default Value
b1
Unit
-
Reset Required
None
11.7.4 Left Button Function
Logical Name
DigitalIO.Button.Left.Function
Description
Defines the function assignment for the left button.
0x00: The button has no function.
0x01: Unlocks the scan function
0x04: Starts a new scan. In Continuous Read Mode it also stops a scan.
0x20: Toggles the trigger mode between Single Read Mode and Continuous Read Mode.
Possible Values
0x00: No function
0x01: Unlock scan function
0x04: Start/Stop scan
0x20: Switch trigger mode
Default Value
0x04
Unit
-
Reset Required
None