IDENTIFICATION
ID HyWEAR compact
11 Configuration Parameters
Page 24 of 41
11 Configuration Parameters
Configuration Parameters
Via the configuration parameters, various settings can be made, e.g. assigning a device ID, selecting
different scan settings or options for the connection to the host. To configure the ID HyWEAR compact the
software “HyWEAR Config Tool” is required, which can be obtained from the FEIG ELECTRONIC download
area. Please use the login data, which you can find in the manual.
11.1 Device Settings
11.1.1 Device ID
Logical Name
Device.Identifier.ScannerID
Description
Unique ID that can be assigned by the user. The ID can have a maximum length of 29 bytes and may only consist of
printable ASCII characters:
!"#$%&'()*+,-./0123456789:;<=>?
@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^_
`abcdefghijklmnopqrstuvwxyz{|}~
Possible Values
Default Value
Unit
-
Reset Required
None
11.1.2 Auto-Power-Off
Logical Name
PowerManagement.AutoPowerOff
Description
Defines the timespan after which the reader automatically switches off. The timespan is always re-triggered when the
trigger button is pressed and a new scan process is started. In Continuous Read Mode the timespan is re-triggered
every time a tag or barcode is read.
If the parameter is set to "65535", the reader will stay on.
Possible Values
1...65535
Default Value
600
Unit
s
Reset Required
Hard
11.1.3 Response Timeout
Logical Name
OperatingMode.ScanMode.Transmission.Timeout
Description
Defines the timeout for a response from the host.
Possible Values
1...255
Default Value
3
Unit
s
Reset Required
Hard