7
For the oil:
Replace the lubricating oil after 100 hours of use; Unscrew the oil plug when
changing the oil. Add lubricating oil using a funnel. However, it is
recommended to change the oil after every 500 hours. Fill the oil when the
ambient temperature is above 10
℃
: recommended oil: recommended SAE30
or L-DAB100 compressor oil,
For the air filter:
The air filter should be cleaned at least every month.
The air compressor must be kept away from all flammable materials. The
compressor should not be used in such applications unless appropriate
additional precautions are taken;
High oil viscosity during cold start, clogged oil filters or malfunction of the valve
can result in oil failure.
There is an overload protector on the compressor (12A). If the current exceeds
12A, the overload protector will start and stop the compressor automatically.
After 2 ~ 3 minutes, press the overload protector button to restart the
compressor.
The ambient temperature for the air compressor is 5 ~ 40 degrees.
Use the air compressor oil according to the ambient temperature for the air
compressor (5 ~ 40 degrees).
The user must provide for the installation of pressure relief devices and other
protective devices. There is a safety valve on the air compressor that starts
automatically at a pressure of 8.8 bar.
Intended use
This product is suitable for the removal of dust and plastic. It can also be used
to inflate, clean, air-clean, etc.
Do not use this tool for other purposes. Follow the instructions below to
properly use the tool and avoid injury
VI.
Preparation before use
Fit the wheels delivered with the machine.