Feider Machines FC200L Скачать руководство пользователя страница 13

 

 

11 

 

IX. Transport and storage 

  Do not tilt the compressor during transport to avoid spilling the compressor oil. 

  Do not put objects on the compressor during transport. 

  The machine is heavy; it must  be carried to two people for the movement or 

using a lifting tool for loading.   

  Clean the compressor before storing it in a dry, ventilated and dust-free place. 

 

X.  Troubleshooting   

Problem 

Causes   

Solutions 

Motor 

doesn’t 

work   

 

(1)  Fuse  blown,  or  circuit 

breaker tripped 

(2)  Failure  of  electrical 

connection wires 

(3) Overheated motor 

(4) Pressure switch fault 

(5) Engine fault 

(6) Tightening of the main 

compressor 

(1)  Check,  change  the  fuse, 

switch on the circuit breaker. 

(2) Check and repair 

   

(3)  Press  the  reset  button  or 

wait for an automatic restart 

(4) Repair or replace 

(5) Check and repair 

(6) Check and repair 

Low pressure 

(1)  Air  leak  in  the  safety 

valve. 

(2)  Air  filter  more  or  less 

clogged. 

(3) Defectiveness in other 

valves 

(1)  Check,  repair,  change  if 

necessary. 

 

(2) 

Clean, 

change 

if 

necessary 

 

(3) Check, change if 

necessary 

Clamping the 

main 

compresso

(1) Moving parts overheated 

due to lack of oil. 

(2) Moving parts are 

damaged or blocked by a 

foreign object. 

Check compressor components 

such as crankshaft, bearing, 

connecting rod, piston, piston 

rings, etc., and replace if 

necessary. 

Presence of 

trace of oil 

in the air 

  (1)  Viscosity  of  the  oil  is 

not appropriate 

(2)  Too  much  oil  in  the 

crankcase 

(3) Overheated compressor 

 

(4) Clogged air filter 

(1)  Change  the  oil,  use  the 

non-detergent  oil  SAE30  or 

SAE20 

(2) Evacuate the overflow 

(3) Readjust the control valve 

and lower the pressure level 

(4) Clean the air filter, change 

if necessary 

Содержание FC200L

Страница 1: ...ORIGINAL INSTRUCTIONS COMPRESSOR INSTRUCTION MANUAL FC200L Feider ZI 32 RUE ARISTIDE BERGES 31270 CUGNAUX FRANCE Read instructions before use Keep for future reference ...

Страница 2: ...o handle highly reliable and quiet it is suitable for many applications in the mechanic and chemical industries for spraying and decorating for automatic control systems as well as in any other area requiring compressed air II DESCRIPTION 1 Wheel 2 Transport handle 3 Air tank 4 Fan and fan cover 5 Compressor 6 Transport handle 7 Pressure gauge 8 Exit valve ...

Страница 3: ...ntermediate temperature 170 200 discharge temperature 10 40 Pressures 0 Bar Intermediate pressure and discharge 0 8Bar Pressure and limiting temperatures of the lubrication system 8Bar 200 Note Noise emission was measured according to the expected conditions by the standards EN1012 and EN ISO 2158 IV Delivery checking After unpacking the machine check the contents of the carton for the possible pr...

Страница 4: ...ructions given in the manual will help you to use the device more efficiently and to reduce the risks Do not use the portable compressor with the door or fence open Read instruction manual Wear hearing protection Do not open the valve before connecting the air hose The device can turn on automatically without warning Risk of high temperature Risk of electric shock ...

Страница 5: ...here is a risk of fire or explosion 3 Protection against electric shock Avoid getting your body in contact with grounded surfaces such as pipes radiators cooking modules refrigerators 4 Keep children away from the work area Never let people touch the compressor the power cable or the extension cord 5 Store the compressor properly If you do not use the compressor keep it in a dry place out of the r...

Страница 6: ...nsion cords designed for this purpose 16 Always be on your guard Watch your work Use common sense Do not use the compressor if you are tired 17 Check for faulty or damaged parts of your compressor Before using your compressor again we strongly recommend that you carefully check the protective accessories and other parts to see if the unit will work properly Check that the moving parts are properly...

Страница 7: ...formed gases that can move in the breathing air must be kept at acceptable levels C Specific safety instructions 1 Before turning the machine mount the air filter vacuum breaker wheels and pads Fig 2 Fig 2 2 Never unscrew the connecting pieces when the tank is pressurized 3 Never disassemble an electrical component before unplugging the unit 4 Never adjust the safety valve without reason 5 Never u...

Страница 8: ... off immediately 19 If the motor gets stuck due to excessively high temperature stop and then disconnect the machine and find the cause 20 If at a pressure greater than 8 bar the machine does not stop automatically immediately switch off the machine by hand and find the cause 21 If a strange noise has occurred turn off the machine immediately and look for the cause 22 If the oil level in the compr...

Страница 9: ...is an overload protector on the compressor 12A If the current exceeds 12A the overload protector will start and stop the compressor automatically After 2 3 minutes press the overload protector button to restart the compressor The ambient temperature for the air compressor is 5 40 degrees Use the air compressor oil according to the ambient temperature for the air compressor 5 40 degrees The user mu...

Страница 10: ...nly 1 The place of use of the compressor must be clean dry and ventilated 2 Conditions of use Use the compressor only at a temperature between 0 and 35 C 3 Be sure to use a voltage 5 of the recommended voltage 4 Maintain the oil level at the red circle filler cap 5 Use SAE30 or L DAB100 compressor oil above 10 C and SAE10 or L DAB68 below 10 C 6 Open the outlet valve set the pressure switch to ON ...

Страница 11: ...l valve and turn it clockwise or counterclockwise to increase or decrease the pressure Fig 4 3 To stop the compressor simply turn the pressure switch knob OFF Fig 4 VIII Maintenance TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the compressor from its electrical outlet before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS ...

Страница 12: ...Check for air leaks to check for air leaks apply soapy water to joints while the Air Compressor is pressurized Look for air bubbles Wipe off any oil or dirt from the compressor To clean the compressor surface wipe with a damp cloth using a mild detergent or mild solvent Draining Moisture from the Tank It must be used daily to release all trapped air and moisture from the Tank This will eliminate c...

Страница 13: ...n or wait for an automatic restart 4 Repair or replace 5 Check and repair 6 Check and repair Low pressure 1 Air leak in the safety valve 2 Air filter more or less clogged 3 Defectiveness in other valves 1 Check repair change if necessary 2 Clean change if necessary 3 Check change if necessary Clamping the main compresso r 1 Moving parts overheated due to lack of oil 2 Moving parts are damaged or b...

Страница 14: ...12 XI Nomenclature ...

Страница 15: ...e Machine 2006 42 EC Directive EMC 2014 30 EU Directive RoHS 2011 65 EU Directive NOISE 2000 14 EC Annex VI 2005 88 EC Also in conformity with the following standards EN 1012 1 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 EN 62321 2009 Sound power level 95 2dB A K 1 96dB A Guarantee sound power level 97dB A Responsible of technical file M Olivier Patriarca Cugnaux 25 10 2018 Philippe MARIE PDG...

Страница 16: ...European Directive 2012 19 EU on waste electrical and electronic equipment and its implementation into national law electrical products used must be collected separately and disposed of at collection points provided for this purpose Talk with your local authorities or dealer for advice on recycling ...

Отзывы: