ECSS E3335
- 18 -
Cleaning Condenser Coil
NOTICE:
Condenser coil or optional air filter must be cleaned a
minimum of twice per month to insure proper refrigeration
performance and prevent compressor failure. In some
environments it may be necessary to clean more frequently.
Failure to clean condenser coil will void condenser warranty.
It is very important that the Condenser coil or optional air filter is cleaned twice
per month to insure proper refrigeration performance and to prevent compressor
failure. In some environments it may be necessary to clean more frequently.
Failure to clean condenser coil will void condenser warranty. This procedure is
for Self Contained models. The remote condenser coil must also be cleaned at
same intervals.
1. Disconnect power to the unit.
2. On ECSS40 Remove the nose panel and on ECSS60 remove the side panel on
left side of case next to the controls.
Carefully vacuum the front surface of condenser coil. Take care not to bend coil
fins with vacuum cleaner nozzle.
-If equipped with optional air filter remove filter and carefully vacuum the front
surface of condenser coil. Take care not to bend coil fins with vacuum cleaner
nozzle. Wash filter using warm soapy water, rinse, and let dry. Apply a generous
coat of filter coat adhesive to both sides of filter. (Filter coat adhesive is available
through any restaurant supply distributor.)
NOTE: Failure to coat filter with a fresh coat of filter adhesive after
cleaning will prevent filter from working properly. Failure to do so
will allow the condenser coil to plug, which will affect refrigeration
performance and could cause compressor failure.
3. Reinstall side panel(s).
VACUUM FRONT
SURFACE OF
CONDENSER COIL
ECSS40 SHOWN