Series ’90 Cold Deli Display
Page 8
ELECTRICAL INFORMATION &
GROUNDING
This Case Must Be Grounded
All case electrical connections must be performed only by a licensed electrician.
All electrical wiring hookups must be done in accordance with all applicable local, regional, or
national electrical standards.
A separate circuit for each display case is recommended to prevent other appliances on the same
circuit from overloading the circuit and causing malfunction.
The electrical service must be grounded upon installation.
This unit is designed for permanent connection to a power source. See the electrical data plate
located at the rear of the case for proper circuit size and wire ampacity.
Connect a separate 115 Volt, 60 HZ, 1 Phase power supply to the display case junction box and a
separate 115 Volt, 60 HZ, 1 Phase power supply to the appliance receptacle junction box.
The electrical connection boxes are accessible from the rear of the case. See diagram below for
location of the field wiring connection boxes.
DANGER:
Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.