Series ’90 Cold Deli Display
Page 16
Case Does Not Operate
Check for disconnected power supply.
Check for tripped breaker or blown fuse.
Check that the power switch and thermostat are not “off”.
Pre-Service Checklist
Lights Do Not Operate
Check that the light switch is on.
Be sure light is properly seated in the sockets.
Check that light cords are tight in the sockets.
Case Temperature Too Warm
Check that the cold air inlet and outlet slots are not blocked.
Be sure the front glass is closed tightly and back doors are closed.
Check for cold air flow. Lack of adequate cold air flow could be a defective evaporator fan
or blocked evaporator coil. Check that paper or foreign material is not blocking the
evaporator. If the evaporator coil is blocked due to excessive frost, turn the thermostat
knob to the “off” position for approximately one hour with the power switch in the “on”
position to defrost. Excessive frost will build up if the case is operated with the doors open.
Glass Fogging
Check ambient- case is designed to operate in an environment of 75F and 55% relative
humidity.
Check case temperature- case is designed to operate between 38F and 42F.
Check that nothing is blocking the warm air vents in the glass handle.
Check that warm air is being blown evenly across the front glass surface. If the air is not
blowing or is not blown evenly, service is required.
Check that the air flow is not being disturbed by a nearby fan or air duct.
Содержание 204-SN8CDBLK
Страница 22: ...Series 90 Cold Deli Display Page 22 WIRING DIAGRAM MAIN WIRING SELF CONTAINED ...
Страница 23: ...Series 90 Cold Deli Display Page 23 WIRING DIAGRAM MAIN WIRING REMOTE ...
Страница 24: ...Series 90 Cold Deli Display Page 24 WIRING DIAGRAM LIGHTS 48 59 ...
Страница 25: ...Series 90 Cold Deli Display Page 25 WIRING DIAGRAM LIGHTS 77 ...