Series ’90 Cold Deli Display
Page 19
REFRIGERATION & ELECTRICAL DATA
REMOTE MODELS
SN4CD-R
SN6CD-R
SN8CD-R
Refrigerant Charge
R-22
R-22
R-22
ALL MODELS ARE 115 VOLT, 1 PHASE, 60 HERTZ, 2 WIRE
AMPS
AMPS
AMPS
Evaporator Fan Motor (2)
0.5 ea.
0.5 ea.
0.5 ea.
Anti-Fogging Fan Motor (2)
0.5 ea.
0.5 ea.
0.5 ea.
Lights
1.2
1.3
1.7
Condensate Evaporator
1.6
1.6
1.6
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit
Ampacity.
Each model is equipped with a general purpose receptacle, requiring a separate electrical circuit of 120V,
15Amps. This circuit must be wired in accordance with the National Electrical Code.