39
Installation, Maintenance, and Service Manual
Federal Signal
www.fedsig.com
Getting Technical Support and Service
After servicing the light bar, perform the Light Bar Test to ensure that all LEDs light
properly by following these steps:
1.
Apply 12 Vdc (+BAT) to the Light Bar Test control wire (black/white/red) from the
Interface Module.
2.
After all LEDs flash in sequence, the Takedown and Alley lights flash.
3.
Remove 12 Vdc from the Light Bar Test control wire.
Testing the Steady Burn LEDs (HotFoot Only)
The Steady Burn LEDs are factory configured per the customer order for one of these
options:
• No Steady Burn (the LEDs flash with the pattern)
• Driver-side Steady Burn
• Driver- and passenger-side Steady Burn
1.
Apply 12 Vdc (+BAT) to the red/white control wire for the Steady Burn LEDs and a
control wire for Mode 1, 2, or 3 (Table 4 on page 14). The LEDs light and stay on
(default setting).
2.
Remove 12 Vdc from the Mode and Steady Burn control wires.
Getting Technical Support and Service
For technical support and service, please contact:
Service Department
Federal Signal Corporation
Phone: 1-800-433-9132
Email: [email protected]
www.fedsig.com
Getting Repair Service
The Federal Signal factory provides technical assistance with any problems that
cannot be handled locally.
Any units returned to Federal Signal for service, inspection, or repair must be
accompanied by a Return Material Authorization (RMA). Obtain a RMA from a local
Distributor or Manufacturer’s Representative.
Provide a brief explanation of the service requested, or the nature of the malfunction.
Address all communications and shipments to the following:
Federal Signal Corporation
Service Department
2645 Federal Signal Drive
University Park, IL 60484-3167