Maintaining and Servicing the Valor
Problem
Corrective Action
The light bar has a delayed
response to being shut off
• Ensure that the connections on the Serial Interface Module are kept
separate from strobe supplies.
• Check all the ground connections, especially on the Serial Interface
Module.
A Flash Takedown/Alley light stays
on with ignition power applied
• Ensure there is no voltage on the corresponding control wire.
• To see if the ROC board is bad, swap it with a similar board.
• Swap the cables on the light bar controller outputs with a known
good output. If the problem moves to another halogen light, send
the light bar controller to Federal Signal for repair.
Takedown/alley lights work, but
Flash Takedown/Alley lights do not
work
• Ensure that 12 Vdc is applied to the takedown and alley (red/black)
control wire.
• Check the 12 Vdc power and negative ground connections to the
light bar to ensure there is enough current.
Only one takedown light turns on
• Check the connections from the light bar controller to the ROC
boards and ensure they are in the proper locations.
SignalMaster LEDs do not light
• Check the switch settings on the Serial Interface Module. Ensure
they are both set for the correct operation.
• Ensure that Switch 4 on SW2 is in the correct position for the
selected operation on the Serial Interface Module and ignition
power was removed and reapplied.
• Check the connections at the SignalMaster controller. If the
controller is a model SS2000SM, ensure that the connector has
power and the ground is connected to pins 10 and 11 on the
SignalMaster plug.
Quick Testing the Valor with the Light Bar Test
LIGHT HAZARDS: To be an effective warning device, this product produces
bright light that can be hazardous to your eyesight when viewed at a close
range. Do not stare directly into this lighting product at a close range or
permanent damage to your eyesight may occur.
IMPORTANT:
Ensure that SW2 Switch 3 in the Serial Interface Module is in the up
position for the Light Bar Test. The down position is ON for the Scene Light, Right option
in light bars with Spectralux Technology (Valor and Valor). For the scene light control
wires see Figure 5 on page 24 or Figure 6 on page 25.
NOTE:
The Light Bar Test does not test the optional Steady Burn LEDs. To test and
configure these LEDs, see “Testing the Steady Burn LEDs (HotFoot Only)” on page
39.