22
Valor
®
Light Bar
Federal Signal
www.fedsig.com
Wiring the Valor in the Vehicle
Internal SignalMaster (Factory Default)
NOTE
: If the SignalMaster is not activated by a control head or an external controller,
the SignalMaster LED heads flash with the selected priority mode (Mode 1, 2, or 3) of
operation.
The Serial Interface Module factory-set for the Internal SignalMaster option. Internal
operation uses the light bar’s built-in SignalMaster controller to generate directional
warning patterns. With internal operation, an external SignalMaster controller is
not needed. A standard low-current switch box can activate the light bar’s internal
SignalMaster controller.
External SignalMaster
External operation uses the Serial Interface Module to drive each SignalMaster
directional warning head independently through an external Federal Signal
SignalMaster controller or SS2000SM series siren Either device provides an
independent ground signal to turn on each head (Figure 4).
Table 5 SignalMaster control wires and warning patterns
Warning
Pattern
Control Wires
Description
LEFT
Red
Rear LEDs flash from right to left
CENTER Green
Rear LEDs flash from center out to both sides
RIGHT
Green/Black/White
Rear LEDs flash from left to right
WARN 1
Orange/Green
Outer LEDs alternate
WARN 2
Orange
Two outer LEDs alternate
WARN 3
Blue/Red
Outer LEDs and two inner LEDs alternate
WARN 4
Red/Green
Outer LEDs and two inner LEDs flash, then the LEDs
between the inner and outer LEDs
FAST
White/Red
Operates the selected pattern 50 percent faster