12
General Description
UltraVoice Remote Interface (UVRI-B)
• Remote download for voice message downloads using IP interface
• Remote monitoring of system and speaker circuits
• Optional cellular, satellite, or broadband IP communications
• Stackable siren functions enable user pre-defined warning scenarios
• 600 ohm I/O for wire line control and status monitoring
• 600 ohm input/output for connection to external amplifiers and fire protection systems
• Built-in 8 ohm (0.7 W) Audio Output. Typically used for cabinet speaker.
• Built-in 10 V/25 V (0.7 W) Audio Output. Typically used to interface 100 W optional
amplifier.
• Monitoring and control of standard amplifier for voltage, current, and status
• Two transceiver ports for radio communications
• Built-in level meter to set and monitor receive level for radio interface
• VOX to provide carrier detect for primary transceiver port
• Optional noise monitoring for automatic level control
• Real-time battery voltage monitoring
• Ambient noise level monitoring with automatic volume control requires microphone
X-SM1-FS1
• Supervised and fault monitored TC1/TC2 Fire Alarm Panel Interface
• Local Audible and Visible Trouble Indicators
Communications Link
When the UVRI-B is equipped with a communications interface, the following interface
parameters require configuration:
1. Unit Type
2. RF Frequency
3. Security Key
4. 128/256-bit Encryption Key
5. Unit Address
6. Configuration Jumper Settings
Unit Type
The Federal Signal Commander System requires configuration based on the
communications method. See the Commander Software Manual for configuration
information.