![Federal Signal Corporation Legend LGD Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/federal-signal-corporation/legend-lgd/legend-lgd_installation-operation-and-service-manual_3835358053.webp)
Appendix A: Wiring Schematics
53
Installation, Operation, and Service Manual
Federal Signal
www.fedsig.com
Schematic
A 2
Typical connections with a SignalMaster controller (External control)
+
−
TYPICAL CONNECTIONS, EXTERNAL CONTROL SIGNALMASTER
IG
1A
WHT
BLK
RED
40 A
CAT5
BLK
BLK/WHT
WHT/RED
RED/GRN
BLU/RED
ORG
ORG/GRN
GRN/BLK/WHT
GRN
RED
BLU (MODE 1)
BLU/WHT (MODE 2)
RED/BLK (FL HAL)
BLK/RED (MODE 3)
LEGEND LIGHT BAR
WHT/BLK (TD)
ORG/RED (R. AL)
GRN/BLK (L. AL)
SWITCH BOX (REMAINING CONNECTIONS
PER DEVICE INSTRUCTIONS BOX)
BLU
YEL
GRY
VIO
ORG
GRN
BRN
WHT
SIGNALMASTER CONTROLLER (REMAINING
CONNECTIONS PER DEVICE INSTRUCTIONS)
290A6002B
12 V BA
TTER
Y
MOVE SW2 DIP
SWITCH 4
TO
THE UP
POSITION FOR EXTERNAL
SIGNALMASTER CONTROL