![Federal Signal Corporation Legend LGD Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/federal-signal-corporation/legend-lgd/legend-lgd_installation-operation-and-service-manual_3835358043.webp)
Maintaining and Servicing the Legend
43
Installation, Operation, and Service Manual
Federal Signal
www.fedsig.com
Figure 16 Lip seal on edge of plastic dome
290A5990B
LIP SEAL FINS
BASE
Adjusting the Aim of the HotFoot LED Assemblies
(LGD45 and LGD53 Only)
You can horizontally adjust the aim of the LED assemblies by positioning them
straight, at 45 degrees or at 90 degrees. Each position has ±10 degrees of
adjustment.
Figure 17 Adjusting the aim of the LED assembly
290A6122-01
TWO PHILLIPS SCREWS SECURE LED
ASSEMBLY TO MOUNTING PLATE
PHILLIPS SCREW SECURES LED
MOUNTING PLATE TO FOOT
To adjust the aim of the HotFoot LED assemblies:
1.
Remove the Phillips Plastite
®
screw that secures the LED mounting plate to the
foot. See Figure 17 on page 43.
2.
Lift and slide the LED assembly off the foot just far enough to invert the
assembly.
3.
Loosen (or remove for a major adjustment) both Phillips Plastite screws
securing the LED assembly to the mounting plate.