Maintaining and Servicing the Integrity
35
Installation, Maintenance, and Service Manual
Federal Signal
www.fedsig.com
Maintaining and Servicing the Integrity
This section describes how to maintain and service the Integrity light bar. Establishing a
regular maintenance and inspection schedule extends the life of the light bar and ensures
safety. For service, support, or replacement parts, contact the Federal Signal Service
Department at 1-800-433-9132, 7 am to 5 pm, Monday through Friday (CT). See Table 10
on page 43 for replacement parts and part numbers.
SHOCK HAZARD: Disconnect ALL power to the light bar before any maintenance
is performed. Failure to do so may result in property damage, serious injury, or
death.
BURN HAZARD: After prolonged operation, the unit gets hot and can cause burns.
Do not touch the unit while or shortly after it has been operating. Always allow the
unit to cool before handling it.
HEAVY OBJECT: Use lifting aids and proper lifting techniques when removing or
replacing this product. Failure to follow this warning may cause personal injury.
Installing the Filler Strips (Sponge Cords)
To reduce the potential for a high-speed noise, use the one enclosed sponge cord
(P/N 864900707-84) to fill the carriage bolt slots after adjusting the mounts to their final
position.
To install the sponge cords:
1.
Adjust the mounting feet to their final position. See Figure 14.
Figure 14 Locations of ROC PCBs
INSTALL SPONGE
CORDS HERE
2.
Starting at one end, press the sponge cord fully into slot. Cut off the excess cord.
3.
Repeat step 2 with the cut-off piece for the other slot.