RECOGNIZE SAFETY SYMBOLS,
WORDS AND LABELS

What You Need To Know About
Safety Instructions

Warning and Important Safety Instructions appearing in
this manual are not meant to cover all possible
conditions and situations that may occur. Common
sense, caution and care must be exercised when
operating or cleaning tools and equipment.

Always contact your dealer, distributor, service agent or
manufacturer about problems or conditions you do not
understand.

DANGER

indicates an imminently hazardous situation

which, if not avoided, will result in death or serious
injury.

This is the safety alert symbol. It is used to alert you

to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible
injury or death. 

WARNING

indicates a potentially hazardous situation

which, if not avoided, could result in death or serious
injury.

CAUTION

indicates an potentially hazardous situation

which, if not avoided, may result in minor or moderate
injury.

CAUTION

used without the safety alert symbol

indicates a potentially hazardous situation which, if not
avoided, may result in property damage.

DANGER

DANGER

DANGER

WARNING

CAUTION

CAUTION

Electrical Shock Hazard

• Plug unit only into a grounded electrical outlet.
• Do not use an extension cord or plug adapter with

this unit. Do not alter cord or plug end. Do not
remove warning label on cord.

• Do not operate unit with decorative front or filter

removed. 

• If the air conditioner has a serial plate rating of 115

volts and greater than 7.5 amps, it must have its
own fuse or circuit breaker, and no other device or
unit should be operated on that fuse or circuit
breaker.

• If the air conditioner has a serial plate rating of 230

volts, it must have its own fuse or circuit breaker,
and no other device or unit should be operated on
that fuse or circuit breaker.

• We recommend that a qualified electrician install

unit in accordance with the National Electrical Code
and local codes and ordinances.

• Use copper conductors of correct wire gauge and

protector size only.

250V

30A

250V

15A

125V

15A  

250V  

20A

Do not

store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.
The fumes can create a fire hazard or explosion.

DANGER

Important Grounding Requirements

• Air conditioner has a three-prong grounding plug

on the power supply cord, which must be plugged
into a properly grounded three-prong wall
receptacle for your protection against possible
shock hazard. For models up to and including 7.5
amperes, use a grounding type wall receptacle to
match the cord plug.

• For models above 7.5 amperes use a single outlet

grounding type wall receptacle to match the cord
plug.

Do not operate this air conditioner without proper
time delay circuit protection (circuit breaker or fuse).
Refer to serial plate for proper power supply
requirements.

Recommended Wire Sizes

(As installed per building code) :
PROTECTOR SIZEWIRE GAUGE
15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM

Содержание Room Air Conditioner

Страница 1: ...itioner Dehumidifier Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner E N G L I S H Model Number Serial Numbe...

Страница 2: ...ecorative front or filter removed If the air conditioner has a serial plate rating of 115 volts and greater than 7 5 amps it must have its own fuse or circuit breaker and no other device or unit shoul...

Страница 3: ...ry two weeks to avoid overheating caused by air obstruction Do not operate without filter Do not obstruct the air intake area of your air conditioner as this could cause overheating thus activating th...

Страница 4: ...Description of Parts on the Portable Cooling Unit Control Panel Use the electronic control panel to select the mode fan speed set the timer or view the current and set room temperature Air Outlet The...

Страница 5: ...dow panel Window panel extensions Window adapter kit An installation parts kit is packed with your unit in a separate carton Before you discard the packaging that your unit came in please locate the c...

Страница 6: ...ertically as well as horizontally This installaton may also be used for crank style windows fig E 3 Tighten the four screws on the window panel to secure the window panel extensions 4 Close window fig...

Страница 7: ...isplay is room temperature the set temperature is displayed and may be adjusted After 15 seconds the display will revert back to room temperature Temperature is adjustable in Cool Heat and Dehumidify...

Страница 8: ...he number of hours the unit is set until it begins operation To turn timer off press the timer button Before starting this unit 1 Select a suitable location making sure you have a level surface with n...

Страница 9: ...th the front of the filter toward you 5 To dry the filter thoroughly run your unit in fan mode for a few minutes Remember only a clean filter works properly and delivers top efficiency at every settin...

Страница 10: ...make the recommended checks If it appears that service or parts are still required see your warranty How to Obtain Warranty Service or Parts Please have the model number and serial number with you wh...