background image

8

Draining excess water

Condensed water may accumulate in the unit. If the

internal tank becomes full, the Warning Light will shine
and the unit will not operate until the unit has been
drained.

First, uplug electrical cord from wall outlet. Then, drain
excess water from the tank by placing a pan under the
drain valve, removing the drain plug, and letting the
water drain into the pan. 

When the water stops draining out, replace the drain
plug, and remove the pan of water. Operate the air
conditioner in fan mode to dry the interior of the unit.

Always drain the unit before putting it into storage.

Cleaning and Maintenance

• The unit has an air filter that must be cleaned with

water every two weeks and put back in the unit after it
is completely dry.

• The air discharge grille can be cleaned with a rag or

sponge, warm water and mild detergent.

• Never use hot water, bleach, gasoline, acids, cleaning

fluid or a brush to clean the unit. This will damage the
cabinet and the air discharge area.

• Do not wash the unit with a hose.

Cleaning the filter.

1. Turn Power OFF.
2. Remove the air filter by grasping the bottom  and

pulling it up and out of the unit.

3. Wash in hot soapy water, rinse and shake dry.
4. Replace the filter with the front of the filter toward you. 
5. To dry the filter thoroughly, run your unit in fan mode

for a few minutes. Remember, only a clean filter works
properly and delivers top efficiency at every setting.

Air Conditioner Remote Control 

Batteries:  Remove the cover on the back of the remote
controller and insert the batteries with the (+) and (-)

poles pointing in the
proper direction.

Drain Valve

Make sure unit is unplugged before performing
any maintenance procedure.

Proper use and care of
your air conditioner will
help ensure longer life of
the unit. It is
recommended to have a
professional annually
inspect and clean the coils
and condensate water
passages. Expense of
annual inspection is the
consumer’s responsibility.

7

8

CAUTION

Failure to keep air filter clean will result in poor air
circulation. DO NOT operate without filter. This can
render the unit inoperative.

CAUTION

• Use only AAA or IEC R03 1.5V batteries.
• Do not attempt to recharge the supplied batteries
• All batteries should be replaced at the same time.
• Do not dispose of the batteries in a fire as they may

explode.

• Do not mix old and new batteries.
• Do not install the batteries with the polarity (+/–)

reversed.

• Do not mix alkaline, standard (carbon - zinc), or

rechargeable (nickel-cadmium) batteries.

• Keep batteries and other things that could be

swallowed away from young children. Contact a
doctor immediately if an object is swallowed.

E

N
G

L

I

S

H

CAUTION

Содержание Room Air Conditioner

Страница 1: ...itioner Dehumidifier Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner E N G L I S H Model Number Serial Numbe...

Страница 2: ...ecorative front or filter removed If the air conditioner has a serial plate rating of 115 volts and greater than 7 5 amps it must have its own fuse or circuit breaker and no other device or unit shoul...

Страница 3: ...ry two weeks to avoid overheating caused by air obstruction Do not operate without filter Do not obstruct the air intake area of your air conditioner as this could cause overheating thus activating th...

Страница 4: ...Description of Parts on the Portable Cooling Unit Control Panel Use the electronic control panel to select the mode fan speed set the timer or view the current and set room temperature Air Outlet The...

Страница 5: ...dow panel Window panel extensions Window adapter kit An installation parts kit is packed with your unit in a separate carton Before you discard the packaging that your unit came in please locate the c...

Страница 6: ...ertically as well as horizontally This installaton may also be used for crank style windows fig E 3 Tighten the four screws on the window panel to secure the window panel extensions 4 Close window fig...

Страница 7: ...isplay is room temperature the set temperature is displayed and may be adjusted After 15 seconds the display will revert back to room temperature Temperature is adjustable in Cool Heat and Dehumidify...

Страница 8: ...he number of hours the unit is set until it begins operation To turn timer off press the timer button Before starting this unit 1 Select a suitable location making sure you have a level surface with n...

Страница 9: ...th the front of the filter toward you 5 To dry the filter thoroughly run your unit in fan mode for a few minutes Remember only a clean filter works properly and delivers top efficiency at every settin...

Страница 10: ...make the recommended checks If it appears that service or parts are still required see your warranty How to Obtain Warranty Service or Parts Please have the model number and serial number with you wh...

Отзывы: