2
DANGER
•
Do not
remove or modify this plug
•
Do not
use as an on/off switch
•
Do not
use outdoors
•
Do not
push furniture against or place furniture on the
electrical cord. This can trip the test switch and/or
damage the cord and become a potential condition
for arcing
•
Do not
attempt to repair the cord. If the cord requires
replacement, call an authorized servicer.
• The Arc Detection Device is not a Ground Fault
Interrupter and should not be used as such
• The Arc Detection Device contains an electronic circuit
board and should not be submerged or exposed to
water spray
Power Cord with
Arc Detection Device
The power cord supplied with this air conditioner is
equipped with an Arc Detection Device designed to shut
off power to the unit when it senses an arc fault condition.
An arc fault is an unintentional electrical discharge that
occurs when electrical products or wires are damaged,
aged, or improperly used. An arc fault can be potentially
hazardous if left undetected.
WARNING
•
Do not
cut, alter or remove any of the expanded
polystyrene (styrofoam) inside this air conditioner.
•
Do not
introduce objects in the air discharge area. This
could cause permanent damage.
•
Do not
pour liquids on the air conditioner as this could
cause a malfunction. With the unit unplugged, use a
damp cloth for cleaning the unit.
•
Do not
use strong solvents to clean the air conditioner.
• Clean the air conditioner filter every two weeks to
avoid overheating caused by air obstruction. Do not
operate without filter.
•
Do not
obstruct the air intake area of your air
conditioner, as this could cause overheating, thus
activating the unit’s security switch and shutting off the
unit.
•
Do not
block air circulation to outside louvers of
cabinet.
•
Do not
block air flow inside with blinds, curtains, or
furniture, or outside with shrubs, enclosures, or other
buildings.
•
Do not
run the air conditioner with an outside
protective cover in place. This could result in fire or
mechanical damage within the air conditioner.
• Carefully inspect the location where the air conditioner
will be installed. Be sure it will support the weight of
the unit over an extended period of time.
Use two or more people to move and install air
conditioner. Failure to do so can result in back or
other injury.
Resetting
If the Arc Detection Device has tripped, the reset
button will pop up.
Follow these steps to reset the Arc Detection Device:
1.
Unplug unit from electrical outlet
2.
Press the reset button
3.
Plug the unit back into electrical outlet
4.
Check to see if power has returned to the unit
Testing
You should test the Arc Detection Device equipped
power cord monthly, after every major electrical storm,
or if power to your Room Air Conditioner has been
interrupted.
Follow these steps to test the Arc Detection Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Press test button. Unit should trip and reset button will
pop up.
5. Press reset button again for use
E
N
G
L
I
S
H
CAUTION
CAUTION